ARP598 PROCEDURE FOR THE DETERMINATION OF PARTICULATE CONTAMINATION OF HYDRAULIC FLUIDS BY THE PARTICLE COUNT METHOD

Reaffirmed

11/01/1991

Features
Issuing Committee
Scope
Content
This test describes a self-checking procedure for the determination of particulate contaminant five microns or greater in size in hydraulic fluids by the particle count method. A maximum variation of two to one (±33% of the average of two runs) in results should be expected for replicate counts on the same sample, providing that the procedure is followed closely and the precautions presented on pages 10 and 11 of the procedure, regarding manipulation, check samples and self-checking aspects, are observed.
Meta TagsDetails
DOI
https://doi.org/10.4271/ARP598
Pages
11
Citation
SAE International Recommended Practice, PROCEDURE FOR THE DETERMINATION OF PARTICULATE CONTAMINATION OF HYDRAULIC FLUIDS BY THE PARTICLE COUNT METHOD, SAE Standard ARP598, Issued March 1960, https://doi.org/10.4271/ARP598.
Additional Details
Publisher
Published
Nov 1, 1991
Product Code
ARP598
Content Type
Recommended Practice
Status
Reaffirmed
Language
English