Results
This SAE Standard provides test procedures for air and air-over-hydraulic disc or drum brakes used for on-highway commercial vehicles over 4536 kg (10000 pounds) GVWR. This recommended practice includes the pass/fail criteria of Federal Motor Vehicle Safety Standard No. TP-121D-01.
This SAE Recommended Practice provides minimum performance requirements and uniform procedures for fatigue testing of wheels intended for normal highway use and temporary use on passenger cars, light trucks, and multipurpose vehicles. For heavy truck wheels and wheels intended to be used as duals, refer to SAE J267. For wheels used on trailers drawn by passenger cars, light trucks, or multipurpose vehicles, refer to SAE J1204. These minimum performance requirements apply only to wheels made of materials included in Tables 1 to 4. The minimum cycles noted in Tables 1 through 4 are to be used on individual test and a sample of tests conducted, with Weibull Statistics using two parameter, median ranks, 50% confidence level, and 90% reliability, typically noted as B10C50.
This SAE lab test procedure should be used when performing the following specialized weathering tests for wheels; Florida Exposure, QUV, Xenon and Carbon Weatherometer. In addition to these procedures, some additional post-weathering tests may be specified. Please refer to customer specifications for these requirements.
This SAE Recommended Practice is intended as a guide toward standard practice and is subject to change to keep pace with experience and technical advances. This document establishes additional performance requirements and provides test methods and requirements to evaluate the suitability of materials intended for optical applications in motor vehicles. The tests are intended to determine physical and optical characteristics of the materials only. Performance expectations of finished assemblies, including plastic components, are to be based on tests for lighting devices, as specified in SAE Standards and Recommended Practices for motor vehicle lighting equipment. Glass and materials inclusive to the light source are not in scope for this method.
This specification covers a copper-beryllium alloy in the form of bars and rods (see 8.5).
These general guidelines and precautions apply to personnel operating directional drilling tracking equipment when used with horizontal directional drilling (HDD) machines as defined in ISO 21467:2023.
SAE J2998 defines the recommended information content to be included for documenting dynamical models used for simulation of ground vehicle systems. It describes the information that should be compiled to describe a model for the following user applications or use cases: (1) exchange, promotion, and selection; (2) creation requests; (3) development process management; (4) compatibility evaluation; (5) testing-in-the-loop simulations with hardware and/or software; (6) simulation applications; and (7) development and maintenance. For each use case, a model description documentation (MDD) template is provided in the appendices to facilitate model documentation. In addition, an example of a completed model documentation template is provided in the appendices.
This document covers the recommended lighting performance and design criteria for: Left Forward Navigation Position Lights (Red) Right Forward Navigation Position Lights (Green) Rear Navigation Position Lights (White) Anticollision Lights. AS8017 provides for the following classes: Class I Rotorcraft, Class II Fixed Wing, and Class III Fixed Wing and Rotorcraft. Possible design requires include but are not limited to: Red Flashing Lights Top and Bottom Fuselage White Flashing Strobe Lights Wing Tips and/or Tail Red Flashing Beacon Light on Top of Vertical Tail
This document recommends and sets forth a set of symbols representing the components making up aircraft fuel and oil systems. The intended result is uniformity in system schematics so that they may be easily understood throughout the aerospace industry.
This SAE Recommended Practice describes a laboratory test procedure and requirements for evaluating the characteristics of heavy-truck steering control systems under simulated driver impact conditions, as well as driver entry/egress conditions. The test procedure employs a torso-shaped body block that is impacted against the steering wheel.
The purpose of this SAE Aerospace Recommended Practice (ARP) is to provide recommendations which will lead to the standardization of interior door design and operation in all transport aircraft. Interior doors are broadly classified into two main categories which include egress path doors and non-egress path doors. The scope of this ARP does not include crew rest doors, secondary barriers to the flight deck, or doors incorporated in furniture surrounding passenger seats as defined in AS6960.
This SAE Aerospace Recommended Practice (ARP) is written for individuals associated with the ground-level testing of large and small gas turbine engines and particularly for those who might be interested in constructing new or adding to existing engine test cell facilities.
This specification covers quality assurance sampling and testing procedures used to determine conformance to applicable specification requirements of carbon and low-alloy steel forgings.
This SAE Standard was developed to provide a method for indicating the direction of engine rotation and numbering of engine cylinders. The document is intended for use in designing new engines to eliminate the differences which presently exist in industry.
This specification covers a corrosion- and heat-resistant steel in the form of welding wire.
This specification covers the requirements for silver deposited on metal parts with a copper strike between the basis metal and the silver deposit.
This specification establishes the requirements for an expanded polytetrafluoroethylene (ePTFE) in the form of sealing tape, gaskets, or sheets requiring no mixing or curing.
This specification covers a corrosion-resistant steel in the form of investment castings homogenized and solution and precipitation heat treated to 130 ksi (895 MPa) tensile strength.
This SAE Aerospace Information Report (AIR) establishes guidelines for evaluating composite electrical connectors and accessories.
This specification covers a heat-treatable, corrosion-resistant steel in the form of bars, wire, forgings, mechanical tubing, and stock for forging or heading.
This SAE Aerospace Information Report (AIR) covers the design parameters for various methods of humidification applicable to aircraft, the physiological aspects of low humidities, the possible benefits of controlling cabin humidity, the penalties associated with humidification, and the problems which must be solved for practical aircraft humidification systems. The design information is applicable to commercial and military aircraft. The physiological aspects cover all aircraft environmental control applications.
This standard includes ISO 9001:20152 quality management system requirements and specifies additional aviation, space, and defense industry requirements, definitions, and notes. It is emphasized that the requirements specified in this standard are complementary (not alternative) to customer and applicable statutory and regulatory requirements. If there is a conflict between the requirements of this standard and customer or applicable statutory or regulatory requirements, the latter shall take precedence. This International Standard specifies requirements for a quality management system when an organization: a needs to demonstrate its ability to consistently provide products and services that meet customer and applicable statutory and regulatory requirements, and b aims to enhance customer satisfaction through the effective application of the system, including processes for improvement of the system and the assurance of conformity to customer and applicable statutory and regulatory
This specification covers the requirements for application to fasteners of a corrosion and heat resistant aluminum coating material having a thermosetting inorganic binder and the properties of the finished coating.
This document provides the technical requirements for implementing the SAE J1939 Functional Safety Communication Protocol in a manner determined suitable for meeting industry applicable functional safety standards.
This document defines a physical layer having a robust immunity to EMI and physical properties suitable for harsh environments. CAN controllers are available which support the CAN Flexible Data Rate Frame Format. These controllers, when used on SAE J1939-11 networks, must be restricted to use only the Classical Frame Format compliant to ISO 11898-1:2015. These SAE Recommended Practices are intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.
SAE J1939-75 defines the set of data parameters (SPs) and messages (PGs) for information predominantly associated with monitoring and control generators and driven equipment in electric power generation and industrial applications. The data parameters (SPs) and messages (PGs) previously published within this document are published in SAE J1939DA. Applications using the SAE J1939-75 document must refer to SAE J1939DA for the SAE J1939 parameters and messages for monitoring and controlling the power units, e.g., engines and turbines, that power the generators and driven industrial equipment.
SAE J1939-81 (“Network Management”) defines the processes and messages associated with managing the addresses of applications communicating on an SAE J1939 network. Network management is concerned with the management of addresses and the association of those addresses with an actual function and with the detection and reporting of network related errors. Due to the nature of management of addresses, network management also specifies address selection and address claiming processes, requirements for reaction to brief power outages, and minimum requirements for ECUs on the network.
This document describes a physical layer utilizing Unshielded Twisted Pair (UTP) cable with extended stub lengths for flexibility in ECU placement and network topology. Also, connectors are not specified. CAN controllers used on SAE J1939-15 networks must be restricted to use only Classical Frames as defined in ISO 11898- 1. A network which may have legacy controllers cannot tolerate FD Frames. These SAE Recommended Practices are intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include, but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.
Items per page:
50
1 – 50 of 215716