Results
This AIR provides information about the specific requirements for missile hydraulic pumps and their associated power sources.
This SAE Recommended Practice specifies the design and/or evaluation with the specific equipment, conditions, and methods for distributorless battery ignition systems intended for use in various internal combustion engines including automotive, marine, motorcycle, and utility engine applications. The test procedures listed in this document are limited to measurements performed on a test bench only and do not include measurements made directly on engines or vehicles. This standard is not intended to supply information for battery ignition systems used in aircraft applications of any type.
This standard specifies the system requirements for an on-board vehicle-to-vehicle (V2V) safety communications system for light vehicles1, including standards profiles, functional requirements, and performance requirements. The system is capable of transmitting and receiving the SAE J2735-defined basic safety message (BSM) [1] over a dedicated short range communications (DSRC) wireless communications link as defined in the Institute of Electrical and Electronics Engineers (IEEE) 1609 suite and IEEE 802.11 standards [2] to [6].
This report revises ARD50015 document to the AIR format. This report, as was the original, is intended to complement ARP1420C and AIR1419C documents issued by the SAE S-16 Committee on spatial total-pressure distortion. These previous documents addressed only total-pressure distortion and excluded total temperature distortion. The subject of inlet total temperature distortion is addressed in this report with some background and identification of the problem area. The status of past efforts is reviewed, and an attempt is made to define where we are today. Deficiencies, voids, and limitations in knowledge and test techniques for total temperature distortion are identified.
This specification covers four series of electrical connectors (plugs and receptacles) with removable crimp contacts and accessories (see 6.1). AS81511 connectors are not recommended for new design. All AS81511 detail sheets that specified class D and/or H have been cancelled without replacement, therefore all class D and H requirements have been deleted from this specification. Electrical, mechanical and environmental features of these connectors include: Environment resisting at sea level and high altitude. Quick disconnect. RFI/EMI (Radio Frequency Interference/Electromagnetic Interference) protection (includes shell to shell grounding spring members). High density insert arrangements. Low level circuit capabilities. Scoop-proof. Fluid resistant class provided. High temperature class provided. Several voltage service ratings available. Individual contact release from the rear of the connector (series 3 and 4 only).
This specification covers an aircraft-quality, low-alloy steel in the form of seamless tubing.
This specification covers a low-alloy steel in the form of welding wire. Type 2 - copper coated wire was removed from this document (see 8.4).
This specification covers a beryllium aluminum alloy in the form of investment castings.
This document provides vehicle-level data collection, data analysis, and data verification procedures that may be used to verify that an instrument under test (IUT) satisfies the vehicle-level requirements specified in the SAE International (SAE) J2945/1 standard. For the purposes of this recommended practice, “vehicle-level requirements” primarily consist of those requirements which can be verified external to the vehicle. The IUT for these procedures is a configured dedicated short range communications (DSRC) vehicle-to-vehicle (V2V) device as defined in SAE J2945/1 and is installed on a light vehicle. While the IUT is conceptually separated from the vehicle it is installed on, the tests outlined in this document are primarily vehicle-level so the terms “vehicle” and “IUT” can generally be considered interchangeable. Additionally, non-vehicle-level complementary tests, not included in this document, are required to verify that the entire set of requirements specified in SAE J2945/1
This specification covers piston rings fabricated from cast iron.
This SAE Recommended Practice provides a system for marking thermoset rubber parts to designate the general type of material from which the part was fabricated.
This specification covers crimp-style aluminum lug terminals and conductor splices for aluminum aircraft wire. Lug terminals and conductor splices are hereafter called “terminals.”
This SAE Standard was developed to provide a method for indicating the direction of engine rotation and numbering of engine cylinders. The document is intended for use in designing new engines to eliminate the differences which presently exist in industry.
This specification establishes the requirements for anodic coatings on aluminum alloys.
This AIR provides guidance to the EMI test facility on how to check performance of the following types of EMI test equipment: Current probe Line Impedance Stabilization Network (LISN) Directional coupler Attenuator Cable loss Low noise preamplifier Rod antenna base Passive antennas All performance checks can be performed without software. A computer may be required to generate an electronic or hard copy of data. This is not to say that custom software might not be helpful; just that the procedures documented herein specifically eschew the necessity of automated operation.
This SAE Standard covers normalized electric-resistance welded, cold-drawn, single-wall, low-carbon steel pressure tubing intended for use as pressure lines and in other applications requiring tubing of a quality suitable for bending, flaring, forming, and brazing. In an effort to standardize within a global marketplace and ensuring that companies can remain competitive in an international market it is the intent to convert to metric tube sizes which will: Lead to one global system Guide users to preferred system Reduce complexity Eliminate inventory duplications
Corrosion control is always of concern to the designer of electronic enclosures. The use of EMI gaskets to provide shielding often creates requirements that are in conflict with ideal corrosion control. This SAE Aerospace Recommended Practice (ARP) presents a compatibility table (see Figure 1) which has as its objective a listing of metallic couples that are compatible from a corrosion aspect and which still maintain a low contact impedance.
This part of SAE J514 covers general and dimensional specifications for 37 degree flared tube fittings. Also included are 37 degree flared fittings with NPTF pipe threads in Appendix B. These fittings are intended for general application in hydraulic systems on industrial equipment and commercial products. These fittings are capable of providing leak-proof, full flow connections in hydraulic systems operating at working pressures as specified in Table 6. Since many factors influence the pressure at which a hydraulic system will or will not perform satisfactorily, the values shown in Table 6 should not be construed as a guaranteed minimum. For any application, it is recommended that sufficient testing be conducted and reviewed by both the user and fitting manufacturer to assure that performance levels will be safe and satisfactory.
This method is used to define the immunity of electric and electronic apparatus and equipment (products) to radiated electromagnetic (EM) energy. This method is based on injecting the calibrated radio frequency currents (voltages) into external conductors and/or internal circuits of the product under test, measuring the strength of the EM field generated by this product and evaluating its immunity to the external EM field on the basis of the data obtained. The method can be utilized only when it is physically possible to connect the injector to the conductors and/or circuits mentioned before. The method allows: Evaluating immunity of the product under test to external EM fields of the strength equal to a normalized one; Calculating the level of external EM field strength at which the given (including maximum permissible) induced currents or voltages are generated in the equipment under test, or solving the “opposite” task; Finding potentially “weak” points of the product design
This part of SAE J514 covers general and dimensional specifications for NPTF pipe adapters and 30 degree NPSM adapter unions. These fittings are intended for general application in hydraulic systems on industrial equipment and commercial products. These fittings are capable of providing leak-proof, full-flow connections in hydraulic systems operating at working pressures as specified in Table 6. Since many factors influence the pressure at which a hydraulic system will or will not perform satisfactorily, the values shown in Table 6 should not be construed as a guaranteed minimum. For any application, it is recommended that sufficient testing be conducted and reviewed by both the user and fitting manufacturer to assure that performance levels will be safe and satisfactory.
This specification covers a synthetic rubber in the form of sheet, strip, tubing, extrusions, and molded shapes.
This SAE Recommended Practice applies to a decorative lamp(s) installed on the front of motor vehicles. This lamp(s) is intended only to be decorative and is not to impair the effectiveness of any required lighting device. This recommended practice establishes uniformity in use guidelines for the performance, installation, activation, and switching of a front decorative lamp(s).
Items per page:
50
1 – 50 of 215871