A Fire Suppression Analysis for the Altair Project

Event
International Conference On Environmental Systems
Authors Abstract
Content
This paper presents a fire suppression analysis for the Altair project. The architecture of the Altair systems relevant to fire safety is briefly reviewed. This is followed by an outline of a fire safety analysis of the spacecraft including an outline of a probabilistic risk analysis (PRA). The particular emphasis of this analysis is the change in risk as the vehicle moves to lower pressure, higher operating voltage and increased oxygen mole fraction. The analysis shows that all of these changes increase the likelihood and intensity of a fire. The paper then outlines the options for a suppression system followed by a trade analysis of the different options. The candidate systems include inert gas agents (nitrogen, carbon dioxide and helium), water-based systems (spray, mist and foam) and chemically active agents. Chemically active agents are included for reference purposes since they are not likely candidates for the Altair vehicles.
Meta TagsDetails
DOI
https://doi.org/10.4271/2009-01-2511
Pages
8
Citation
Dietrich, D., Ruff, G., and Urban, D., "A Fire Suppression Analysis for the Altair Project," SAE Int. J. Aerosp. 4(1):421-428, 2011, https://doi.org/10.4271/2009-01-2511.
Additional Details
Publisher
Published
Jul 12, 2009
Product Code
2009-01-2511
Content Type
Journal Article
Language
English