- This SAE Recommended Practice is applicable to all engine cooling systems used in (1) Heavy-duty vehicles, industrial applications, and (2) Automotive applications.There are two categories of coolant reservoir tanks covered in the document:
-
a
Pressurized tanks
-
b
Un-pressurized tanks
-
a
- Content
- This recommended practice has been revised to include recommendations from the Task Force team formed during the 2017 Five-Year review:
-
a
Changed document type to Recommended Practice.
-
b
Reformatting the different heading levels to clearly identify the two main engine cooling systems this recommended practice is focused on: (1) Heavy-duty vehicles, industrial and (2) Automotive applications.
-
c
Added Reference SAE specifications in Section 2.
-
d
Defined in Figures 1 and 2 the different identification levels in a surge tank (pressurized) and reservoir tank (un-pressurized).
-
e
Minor changes have been made to clarify various parts of the document.
-