ARP1233 GLAND DESIGN, ELASTOMERIC O-RING SEALS, DYNAMIC RADIAL, 1500 PSI MAX
Reaffirmed
05/01/1995
- Features
- Issuing Committee
- Content
- This document establishes standard gland design criteria and dimensions for dynamic radial O-ring seal applications and provides recommendations for modifying these glands in special applications. There are no provisions in this document for anti-extrusion devices.
- Pages
- 12
- Citation
- SAE International Recommended Practice, GLAND DESIGN, ELASTOMERIC O-RING SEALS, DYNAMIC RADIAL, 1500 PSI MAX, SAE Standard ARP1233, Issued April 1977, https://doi.org/10.4271/ARP1233.