ARP1179C Aircraft Gas Turbine Engine Exhaust Smoke Measurement

Revised

10/01/1997

Features
Issuing Committee
Scope
Content
This SAE Aerospace Recommended Practice (ARP) standardizes test equipment and procedures for the measurement of smoke emission from aircraft gas turbine engines. The procedures included are for determining and reporting the amount of smoke emission. Tests have indicated that the practically achievable precision of the smoke number is within ±3 when the system is properly used as outlined herein. This procedure is not intended for in-flight testing, nor does it apply to engines operating in the afterburning mode.
Meta TagsDetails
DOI
https://doi.org/10.4271/ARP1179C
Pages
13
Citation
SAE International Recommended Practice, Aircraft Gas Turbine Engine Exhaust Smoke Measurement, SAE Standard ARP1179C, Revised October 1997, Issued May 1970, https://doi.org/10.4271/ARP1179C.
Additional Details
Publisher
Published
Oct 1, 1997
Product Code
ARP1179C
Content Type
Recommended Practice
Status
Revised
Language
English

Revisions