Modelling of an Adjustable Generic Simplified Vehicle for Pedestrian Impact and Simulations of Corresponding Reference PMHS Tests Using the GHBMC 50th Percentile Male Pedestrian Simplified Model

CEESAR-Jerome Uriot
LAB PSA Renault-Eric Song, Philippe Petit
Published 2018-11-12 by The Stapp Association in United States
In a previous study (Song et al. 2017), an adjustable generic simplified vehicle buck was developed; eleven PMHS were impacted by the buck representing a SUV, a van and a sedan successively; and biofidelity corridors were established. The objectives of the current study were 1) to develop the computational model of the buck, and 2) to simulate these PMHS tests with the buck model and to assess the biofidelity of the GHBMC 50th percentile male pedestrian simplified model (GHBMC M50-PS). First, coupon tensile tests and static and dynamic compression tests were performed on the steel tubes representing the bonnet leading edge (BLE), the bumper and the spoiler used in the above PMHS tests. Based on these tests, the computational models of the above components were then developed and validated. Next, the buck model was built with the component models, and used to simulate the PMHS tests with the GHBMC M50-PS model. These simulations allowed to evaluate the biofidelity of the GHBMC M50-PS model in terms of 1) impact forces between the pedestrian and the buck,…
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Reference PMHS Sled Tests to Assess Submarining of the Small Female

CEESAR-Jérôme Uriot, Pascal Potier, Pascal Baudrit
Faurecia Automotive Seating-Olivier Richard
Published 2018-11-12 by The Stapp Association in United States
In the last decade, extensive efforts have been made to understand the physics of submarining and its consequences in terms of abdominal injuries. For that purpose, 27 Post Mortem Human Subject (PMHS) tests were performed in well controlled conditions on a sled and response corridors were provided to assess the biofidelity of dummies or human body models. All these efforts were based on the 50th percentile male.In parallel, efforts were initiated to transfer the understanding of submarining and the prediction criteria to the THOR dummies. Both the biofidelity targets and the criteria were scaled down from the 50th percentile male to the 5th percentile THOR female. The objective of this project was to run a set of reference PMHS tests in order to check the biofidelity of the THOR F05 in terms of submarining. Three series of tests were performed on nine PMHS, the first one was designed to avoid submarining, the second and third ones were designed to result in submarining.In the first configuration, no submarining was observed in 3 cases out of 4…
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Update of the WorldSID 50th Male Pelvic Injury Criterion and Risk Curve

CEESAR-Matthieu Lebarbé, Pascal Baudrit
LAB PSA RENAULT-Philippe Petit, Xavier Trosseille
Published 2018-04-03 by SAE International in United States
Petit et al. 2015 and Lebarbé et al. 2016 reported on two studies where the injury mechanism and threshold of the sacroiliac joint were investigated in two slightly oblique crash test conditions from 18 Post Mortem Human Subjects (PMHS) tests. They concluded that the sacroiliac joint fractures were associated with pubic rami fractures. These latter being reported to occur first in the time history. Therefore it was recommended not to define a criterion specific for the sacroiliac joint.In 2012, injury risk curves were published for the WorldSID dummy by Petitjean et al. For the pelvis, dummy and PMHS paired tests from six configurations were used (n = 55). All of these configurations were pure lateral impacts. In addition, the sacroiliac joint and femur neck loads were not recorded, and the dummy used was the first production version (WorldSID revision 1). Since that time, the WorldSID was updated several times, including changes in the pelvis area.In the present study, the two slightly oblique PMHS test configurations of 2015 and 2016 (n = 18) as well as three of the reference…
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

New Reference PMHS Tests to Assess Whole-Body Pedestrian Impact Using a Simplified Generic Vehicle Front-End

Eric Song, Philippe Petit, Jerome Uriot, Pascal Potier
CEESAR-Denis Dubois
Published 2017-11-13 by The Stapp Association in United States
This study aims to provide a set of reference post-mortem human subject tests which can be used, with easily reproducible test conditions, for developing and/or validating pedestrian dummies and computational human body models against a road vehicle. An adjustable generic buck was first developed to represent vehicle front-ends. It was composed of four components: two steel cylindrical tubes screwed on rigid supports in V-form represent the bumper and spoiler respectively, a quarter of a steel cylindrical tube represents the bonnet leading edge, and a steel plate represents the bonnet. These components were positioned differently to represent three types of vehicle profile: a sedan, a SUV and a van. Eleven post-mortem human subjects were then impacted laterally in a mid-gait stance by the bucks at 40 km/h: three tests with the sedan, five with the SUV, and three with the van. Kinematics of the subjects were recorded via high speed videos, impact forces between the subjects and the bucks were measured via load cells behind each tube, femur and tibia deformation and fractures were monitored via…
This content contains downloadable datasets
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Investigation of Pelvic Injuries on Eighteen Post Mortem Human Subjects Submitted to Oblique Lateral Impacts

CEESAR-Matthieu Lebarbé, Pascal Baudrit, Pascal Potier
LAB PSA Peugeot Citroën Renault-Philippe Petit, Xavier Trosseille
Published 2016-11-07 by The Stapp Association in United States
The aim of this study was to investigate the sacroiliac joint injury mechanism. Two test configurations were selected from full scale car crashes conducted with the WorldSID 50th dummy resulting in high sacroiliac joint loads and low pubic symphysis force, i.e. severe conditions for the sacroiliac joint. The two test conditions were reproduced in laboratory using a 150-155 kg guided probe propelled respectively at 8 m/s and 7.5 m/s and with different shapes and orientations for the plate impacting the pelvis. Nine Post Mortem Human Subject (PMHS) were tested in each of the two configurations (eighteen PMHS in total). In order to get information on the time of fracture, eleven strain gauges were glued on the pelvic bone of each PMHS.Results - In the first configuration, five PMHS out of nine sustained AIS2+ pelvic injuries. All five presented sacroiliac joint injuries associated with pubic area injuries. In the second configuration, four specimens out of nine sustained AIS2+ pelvic injuries. Two of them presented sacroiliac joint fractures associated with pubic area injuries. The other two presented…
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Reference PMHS Sled Tests to Assess Submarining

CEESAR-Jérôme Uriot, Pascal Potier, Pascal Baudrit
Faurecia Automotive Seating-Olivier Richard
Published 2015-11-09 by The Stapp Association in United States
Sled tests focused on pelvis behavior and submarining can be found in the literature. However, they were performed either with rigid seats or with commercial seats. The objective of this study was to get reference tests to assess the submarining ability of dummies in more realistic conditions than on rigid seat, but still in a repeatable and reproducible setup. For this purpose, a semi-rigid seat was developed, which mimics the behavior of real seats, although it is made of rigid plates and springs that are easy to reproduce and simulate with an FE model. In total, eight PMHS sled tests were performed on this semi-rigid seat to get data in two different configurations: first in a front seat configuration that was designed to prevent submarining, then in a rear seat configuration with adjusted spring stiffness to generate submarining.All subjects sustained extensive rib fractures from the shoulder belt loading. No pelvis fractures and no submarining were observed in the front seat configuration, but two subjects sustained lumbar vertebrae fractures. In the rear seat configuration, all subjects…
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

A Comparison of Sacroiliac and Pubic Rami Fracture Occurrences in Oblique Side Impact Tests on Nine Post Mortem Human Subjects

CEESAR-Mathieu Lebarbé, Pascal Baudrit, Pascal Potier
LAB PSA Peugeot Citroën Renault-Philippe Petit, Xavier Trosseille
Published 2015-11-09 by The Stapp Association in United States
The WorldSID dummy can be equipped with both a pubic and a sacroiliac joint (S-I joint) loadcell. Although a pubic force criterion and the associated injury risk curve are currently available and used in regulation (ECE95, FMVSS214), as of today injury mechanisms, injury criteria, and injury assessment reference values are not available for the sacroiliac joint itself. The aim of this study was to investigate the sacroiliac joint injury mechanism. Three configurations were identified from full-scale car crashes conducted with the WorldSID 50th percentile male where the force passing through the pubis in all three tests was approximately 1500 N while the sacroiliac Fy / Mx peak values were 4500 N / 50 Nm, 2400 N / 130 Nm, and 5300 N / 150 Nm, respectively. These tests were reproduced using a 150 kg guided probe impacting Post Mortem Human Subjects (PMHS) at 8 m/s, 5.4 m/s and 7.5 m/s. The shape and the orientation of the impacting face of the probe were selected to match the WorldSID pubic Fy and sacroiliac Fy / Mx…
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Proposed Method for Development of Small Female and Midsize Male Thorax Dynamic Response Corridors in Side and Forward Oblique Impact Tests

CEESAR-Pascal Baudrit, Xavier Trosseille
Published 2015-11-09 by The Stapp Association in United States
Despite the increasing knowledge of the thorax mechanics, the effects of inter-individual differences on the mechanical response are difficult to take into account. Several methods are available in the literature to refine the biofidelity corridors or to extrapolate them to other populations (eg: children, small females, large males). Because of the lack of concrete cases, the relevance of the assumptions is rarely investigated.In 2014, Baudrit et al. published data on thorax dynamic responses of small female and midsize male Post Mortem Human Subjects in side and forward oblique impact tests. The impactor mass was 23.4 kg for all the tests and the nominal impact speed was 4.3 m/s. The diameter of the rigid disk was 130 and 152 mm respectively for the small female specimens and for the midsize male specimens. The authors found that the maximum impact force was a function of the total body mass for each loading. They also reported that the ratio of dissipated energy on total deformation energy was almost constant and equal to 0.88.From these observations, a method was…
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Comparison of Kriging and Moving Least Square Methods to Change the Geometry of Human Body Models

CEESAR-Erwan Jolivet, Yoann Lafon, Philippe Petit, Philippe Beillas
Published 2015-11-09 by The Stapp Association in United States
Finite Element Human Body Models (HBM) have become powerful tools to study the response to impact. However, they are typically only developed for a limited number of sizes and ages. Various approaches driven by control points have been reported in the literature for the non-linear scaling of these HBM into models with different geometrical characteristics. The purpose of this study is to compare the performances of commonly used control points based interpolation methods in different usage scenarios. Performance metrics include the respect of target, the mesh quality and the runability. For this study, the Kriging and Moving Least square interpolation approaches were compared in three test cases. The first two cases correspond to changes of anthropometric dimensions of (1) a child model (from 6 to 1.5 years old) and (2) the GHBMC M50 model (Global Human Body Models Consortium, from 50th to 5th percentile female). For the third case, the GHBMC M50 ribcage was scaled to match the rib cage geometry derived from a CT-scan. In the first two test cases, all tested methods provided…
Annotation ability available
   This content is not included in your SAE MOBILUS subscription, or you are not logged in.

Comparison of the Thorax Dynamic Responses of Small Female and Midsize Male Post Mortem Human Subjects in Side and Forward Oblique Impact Tests

CEESAR-Pascal Baudrit, Audrey Petitjean, Pascal Potier
LAB PSA Peugeot Citroën-Renault SA-Xavier Trosseille
Published 2014-11-10 by The Stapp Association in United States
Despite the increasing knowledge of the thorax mechanics in impact loadings, the effects of inter-individual differences on the mechanical response are difficult to take into account. For example, the biofidelity corridors for the small female or large male are extrapolated from the midsize male corridors.The present study reports on the results of new tests performed on small female Post Mortem Human Subjects (PMHS), and compares them with test results on midsize male PMHS. Three tests in pure side impact and three tests in forward oblique impact were performed on the thorax of small female specimens. The average weight and stature were 43 kg and 1.58 m for the small female specimens.The initial speed of the impactor was 4.3 m/s. The mass and the diameter of the impactor face were respectively 23.4 kg and 130 mm. The instrumentation and methodology was the same as for the tests published in 2008 by Trosseille et al. on midsize male specimens. The rib cages were instrumented with accelerometers on the T1, T4 and T12 vertebrae, upper and lower sternum,…
Annotation ability available