This document defines the test procedures and performance limits of steady state and transient voltage characteristics for 12 V, 24 V, or 48 V electrical power generating systems used in commercial ground vehicles.
To provide a procedure to inspect a refrigerant cylinder used in equipment servicing mobile air-conditioning (A/C) systems. This includes the pressure cylinder used for refrigerant recovery/recycling and charging equipment.
This SAE Standard applies to refrigerant vapor compression systems that provide cooling and/or heating for passenger cars, light trucks, and commercial vehicles (on and off road) that use automotive type mobile air conditioning (MAC) systems. Large trucks, buses, and other vehicles that do not use typical automotive A/C systems or use refrigerants not listed in this document are not covered by this standard. This standard covers vehicles with MAC systems using belt driven compressors and electric motor driven compressors. This document provides industry-recognized standards for the design, assembly, and test of MAC systems, including necessary service equipment, and is intended to cover all phases of the lifetime of MAC systems to minimize environmental, health, and safety impacts. The standards listed in this document cover the currently accepted industry guidelines and procedures. The standards can be used as requirements for regulatory authorities to meet minimum environmental
This SAE Standard covers reinforced rubber, reinforced thermoplastic, or otherwise constructed hose, or hose assemblies, intended for conducting liquid and gaseous refrigerants for service connections from mobile air conditioning systems to service equipment such as a manifold gauge set and vacuum pumps or for use internally, in charging stations or service equipment intended for use in servicing mobile air-conditioning systems.
Refrigerant containment is an important part of servicing mobile air-conditioning (A/C) systems. This procedure provides guidelines for technicians for servicing mobile A/C systems and operating refrigerant recycling equipment designed for HFC-134a (R-134a) (described in SAE J2210).
This SAE Standard applies to fluorescent refrigerant leak detection dye injection equipment for use in ultraviolet leak detection when servicing mobile air-conditioning systems.
The purpose of this SAE Recommended Practice is to provide criteria for determining the compatibility of air-conditioning (A/C) system materials/components with candidate retrofit refrigerants intended to replace CFC-12 (R12) in mobile A/C systems originally designed to use CFC-12 (R-12).
This SAE Standard applies to the application of ultraviolet leak detection to service mobile air-conditioning systems.
The purpose of this SAE Standard is to provide equipment specifications for the recovery of HFC-134a (R-134a) refrigerant to be returned to a refrigerant reclamation facility that will process it to the appropriate ARI 700 Standard or allow for recycling of the recovered refrigerant to SAE J2210 specifications by using Design Certified equipment of the same ownership. It is not acceptable that the refrigerant removed from a mobile air-conditioning (A/C) system, with this equipment be directly returned to a mobile A/C system. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar HFC-134a (R-134a) A/C systems.
During service of mobile air-conditioning (A/C) systems, containment of the refrigerant is important. This procedure provides service guidelines for technicians when repairing vehicles and operating equipment defined in SAE J1990.
The purpose of this SAE Recommended Practice is to provide criteria for determining the acceptability of candidate retrofit refrigerants to replace CFC-12 (R-12) in mobile A/C systems originally designed to use CFC-12 (R-12).
The scope of this SAE Recommended Practice is to establish uniform test procedures for passenger cars, to determine whether the system is defined as a defroster or defogger, and to establish minimum performance requirements for each system. A defroster for purposes of this practice is a system which will remove moisture and/or frost from the interior surface of the backlight at −18 °C. A defogger is a system which will remove moisture and/or fog from the interior surface of the backlight at 4 °C. The test procedure is intended to simulate actual conditions by utilizing either a cold room with an appropriate device to introduce air flow over the backlight or a sufficiently large wind tunnel with ambient temperature control. The test procedure and the minimum performance requirements are based on currently available engineering data.
This information applies to refrigerant used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) systems. Systems used on mobile vehicles for refrigerated cargo that have hermetically sealed, rigid pipe, are not covered in this document.
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recycling equipment. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) air-conditioning (A/C) systems. Systems used on mobile vehicles for refrigerating cargo that have hermetically sealed systems are not covered in this document. The equipment in this document is intended for use with refrigerant that has been directly removed from, and intended to be returned to, a mobile A/C system. Should other revisions due to operational or technical requirements occur, this document may be amended.
The purpose of this SAE Standard is to establish the specific minimum equipment performance requirements for recovery and recycling of HFC-134a that has been directly removed from, and is intended for reuse in, mobile air-conditioning (A/C) systems. It also is intended to establish requirements for equipment used to recharge HFC-134a to an accuracy level that meets Section 9 of this document and SAE J2099. The requirements apply to the following types of service equipment and their specific applications: a. Recovery/recycling equipment b. Recovery/recycling - refrigerant charging c. Refrigerant recharging equipment only
The intent of this standard is to establish a framework to assure that all evaporators conforming to its requirements demonstrate an acceptable health and safety environment for vehicle occupants as determined from the completed risk assessment. R-744 and low pressure (i.e., non-transcritical refrigerants with a critical temperature between 85 and 120 °C) mobile air conditioning (MAC) refrigerant evaporators shall meet the testing and labeling requirements of this standard. SAE J639 contains a list of all refrigerants considered acceptable for use in mobile thermal systems for which this standard applies when the refrigerant is used in a direct expansion architecture. SAE J639 also requires an assessment to be performed to minimize reasonable risks in MAC systems. The evaporator (as designed and manufactured) shall be part of that risk assessment, and it is the responsibility of the vehicle manufacturer to ensure all relevant aspects of the evaporator are included. It is the
The automotive air-conditioning service ports task force conducted a field survey with MACS (Mobile Air Climate Systems Association) in June 2021. The scope of this survey was to determine the types of failures reported primarily at member service shops related to automotive air-conditioning service ports.
This standard defines a system for the qualification of standard products for aviation, space, and defense applications. It defines the principles that shall be adhered to when carrying out product qualification; applied in conjunction with the rules and procedures of the CA. The system enables the CA to confirm compliance is achieved and maintained, in accordance with the requirements of its product definition and associated controlling technical specifications by an Original Component Manufacturer (OCM) of standard products. This standard requires an OCM that has been granted product qualification approval to ensure applicable approvals are maintained and renewed in accordance with the CA’s quality system for that qualified product. OCMs and OCM designated Value Added Distributors (VADs) requesting product qualification to this standard, shall as a prerequisite, maintain 9100 standard quality management system certification approval. This certification shall be visible in the Online
This specification covers a corrosion and heat-resistant cobalt alloy in the form of welding rods, coating rods, or wrought wire.
This specification establishes engineering requirements for electropolishing metallic parts and materials using Computer Aided Engineering simulation to reduce the process risks related to electropolishing.
The intended upper bound of this specification is that the particle size distribution (PSD) of powders supplied shall be <60 mesh (250 µm) and that no powder (0.0 wt%) greater than 40 mesh (425 µm) is allowed.
This specification covers a synthetic rubber in the form of a soft wall, smooth bore, collapsing-type hose.
This specification covers the specific requirements for aluminum alloy 7178-T76 bar, rod, shapes, and wire produced by extrusion.
This specification covers an aluminum alloy powder metallurgy product in the form of sheet 0.010 to 0.250 inch (0.25 to 6.35 mm) in nominal thickness.
This specification covers uncoated, round, high carbon steel wire for the fabrication of mechanical springs and wire forms for general purpose use.
This specification covers a Silicone (PVMQ) Rubber compound in the form of molded rings.
This specification covers a copper-beryllium alloy in the form of sand, investment, or centrifugal castings.
This specification covers aluminum alloy sheet laminated with one or more layers of unidirectional aramid fiber/epoxy prepreg. The outer layers are always aluminum alloy.
This specification covers glass roving impregnated with epoxy resin, the resin being partially processed to a "B" stage condition.
This specification covers a polychloroprene (CR) rubber, resin modified, solvent-type contact adhesive in the form of a liquid.
This specification covers a silicone (MQ/VMQ) elastomer that can be used to manufacture product in the form of sheet, strip, tubing, extrusions, and molded shapes. This specification should not be used for molded rings, compression seals, O-ring cord, and molded in place gaskets for aeronautical and aerospace applications without complete consideration of the end use prior to the selection of this material.
This specification covers an irradiated, thermally-stabilized, flame-resistant modified-polychloroprene rubber in the form of thin-wall tubing.
This specification covers an irradiated, thermally-stabilized, modified polyolefin plastic in the form of a thin-wall, heat-shrinkable tubing with a low recovery temperature.
This specification covers the specific requirements for improved exfoliation resistant alclad aluminum alloy 7178-T76 sheet and -T7651 plate. The general requirements are covered in AMS-QQ-A-250. The plate and sheet covered by this specification shall be an integral composite product consisting of a heat-treatable aluminum alloy (7178) core with thin layers of an aluminum alloy (7072) anodic to the core and of approximately equal thickness, bonded to both surfaces
This specification covers polycarbonate sheet.