Results
This document defines the test procedures and performance limits of steady state and transient voltage characteristics for 12 V, 24 V, or 48 V electrical power generating systems used in commercial ground vehicles.
This SAE Aerospace Recommend Practice (ARP) is intended to identify both safety related best practices and unique design considerations of metal halides High Intensity Discharge (HID) lamps and power supplies in aircraft applications.
The following schematic diagrams reflect various methods of illustrating automotive transmission arrangements. These have been developed to facilitate a clear understanding of the functional interrelations of the gearing, clutches, hydrodynamic drive unit, and other transmission components. Two variations of transmission diagrams are used: in neutral (clutches not applied) and in gear. For illustrative purposes, some typical transmissions are shown.
This SAE Aerospace Standard (AS) contains landing gear strength and rigidity requirements which, in combination with other applicable specifications, define the structural design, analysis, test, and data requirements for fixed wing piloted airplanes. These requirements include, but are not limited to, the following: a General specifications: 1 The shock-absorption characteristics and strength of landing-gear units and the strength and rigidity of their control systems and of their carry-through structures. Requirements for wheels, tires, and brakes as they affect air vehicle ground loads are also included. 2 The strength of structures integral with the airplane provided for transmitting catapulting forces to the airplanes, and for engaging shipboard and shore-based arresting gear, and barricades. 3 The strength of anchor-line clamps, and the airplane strength for hoisting, jacking, towing, tie-down, and other ground- or deck-handling conditions. 4 Structural design, analysis, and test
This SAE Recommended Practice is part of the SAE J2534-2/X_0500 set of documents that extends the SAE J2534-1_0500 API (version 05.00) specification, and defines how to implement single wire CAN (SW CAN) within the SAE J2534 API framework. This document details only the changes from SAE J2534-1_0500 and items not specifically detailed in this document are assumed to have not changed. An SAE J2534-2/1_0500 interface shall be compliant to the single wire CAN feature only when all the required functionality in this SAE Recommended Practice is implemented. Any functionality not required for compliance will be specifically marked as “optional” in this document. This document must be used in conjunction with the SAE J2534-2/BA_0500 and SAE J2534-2/RE_0500 documents.
This recommended practice contains dimensions and tolerances for spindles in the interface area. Interfacing components include axle spindle, bearing cones, bearing spacer, and seal. This recommended practice is intended for axles commonly used on Class 7 and 8 commercial vehicles. Included are SAE axle configurations FF, FL, I80, L, N, P, R, U, and W.
In this report, "Cryogenically Fueled Dynamic Power Systems" include all open cycle, chemically fueled, dynamic engine power systems which utilize cryogenic fuels and oxidizers. For nearly all practical present day systems, this category is limited to cryogenic hydrogen or hydrogen-oxygen fueled cycles with potential in future, more advanced systems for replacement of oxygen by fluorine. Excluded from the category are static cryogenic systems (e.g., fuel cells) and chemical dynamic power systems which utilize earth storable propellants.
This document establishes training guidelines applicable to fiber optic technician, quality assurance, or engineer technical training for individuals involved in the manufacturing, installation, support, integration and testing of fiber optic systems. Applicable personnel include: Managers Engineers Technicians Trainers/Instructors Third Party Maintenance Agencies Quality Assurance Production
This SAE Recommended Practice is part of the SAE J2534-2/X_0500 set of documents that extends the SAE J2534-1_0500 API (version 05.00) specification, and defines how to implement HONDA_DIAGH within the SAE J2534 API framework. This document details only the changes from SAE J2534-1_0500 and items not specifically detailed in this document are assumed to have not changed. An SAE J2534-2/4_0500 interface shall be compliant to the HONDA_DIAGH feature only when all the required functionality in this SAE Recommended Practice is implemented. Any functionality not required for compliance will be specifically marked as “optional” in this document. This document must be used in conjunction with the SAE J2534-2/BA_0500 and SAE J2534-2/RE_0500 documents.
The purpose of this ARP is to provide the sample selection criteria and endurance time test procedures for SAE Type I aircraft deicing/anti-icing fluids required for the generation of endurance time data of acceptable quality for review by the SAE G-12 Holdover Time Committee. A significant body of previous research and testing has indicated that all Type I fluids formulated with conventional glycols, as defined in 3.1.1 of AMS1424, perform in a similar manner from an endurance time perspective. This applies to Type I deicing/anti-icing fluids formulated with propylene glycol, ethylene glycol, and diethylene glycol only. As a result, Type I deicing/anti-icing fluids containing these glycol bases no longer require testing for endurance times. The methods described in this ARP shall be employed, however, if endurance time testing of a conventional glycol-based Type I deicing/anti-icing fluid is desired or requested by a fluid manufacturer, operator, or other organization. Fluids
This test method is applicable for rating various materials, such as automotive trim materials and insulation composites, for their ability to resist heat transfer, heat degradation, odor, smoking, and exothermic reaction under prescribed temperature.
This document establishes training guidelines applicable to fiber optic fabricator technical training for individuals involved in the manufacturing, installation, support, integration and testing of fiber optic systems. Applicable personnel include: Managers Engineers Technicians Trainers/Instructors Third Party Maintenance Agencies Quality Assurance Production
This SAE Aerospace Recommended Practice (ARP) provides design, operation, construction, test and installation recommendations for equipment that automatically presents supplemental oxygen masks to cabin occupants in the event of loss of cabin pressure. It specifically covers automatic presentation for transport category aircraft that operate above 30 000 ft (9144 m) altitude. It also provides guidance for similar equipment used in non-transport category aircraft, or aircraft operated below 30 000 ft (9144 m) altitude.
The scope and purpose of this SAE Recommended Practice is to provide a standard pattern or sequence for the manual control of automatic transmissions in passenger cars and light-duty trucks. This generally refers to left hand drive mechanical shift applications.
This SAE Recommended Practice is part of the SAE J2534-2/X_0500 set of documents that extends the SAE J2534-1_0500 API (version 05.00) specification and defines how to implement transmission control protocol (TCP) within the SAE J2534 API framework. This document details only the changes from SAE J2534-1_0500 and items not specifically detailed in this document are assumed to have not changed. An SAE J2534-2/18_0500 interface shall be compliant to the TCP CLIENT feature only when all the required functionality in this SAE Recommended Practice is implemented. Any functionality not required for compliance will be specifically marked as “optional” in this document. This document must be used in conjunction with the SAE J2534-2/13_0500 (ethernet), SAE J2534-2/16_0500 (IPv4), SAE J2534-2/15_0500 (IPv6), SAE J2534-2/BA_0500, and SAE J2534-2/RE_0500 documents.
Like the technologies to which it contributes, the science of instrumentation seems to be expanding to unlimited proportions. In considering instrumentation techniques, primary emphasis was given in this section to the fundamentals of pressure, temperature, and flow measurement. Accent was placed on common measurement methods, such as manometers, thermocouples, and head meters, rather than on difficult and specialized techniques. Icing, humidity, velocity, and other special measurements were touched on briefly. Many of the references cited were survey articles or texts containing excellent bibliographies to assist a more detailed study where required.
This slash document collects general reference material related to gaseous oxygen system flow requirements and sizing calculations. This document will assist oxygen system equipment designers and operators to establish systems and equipment requirements. The document consists of charts, tables, system schematics, system requirements, and sample calculations for system sizing.
This SAE standard establishes the requirement for suppliers to plan a reliability program that satisfies the following three requirements: a The supplier shall ascertain customer requirements b The supplier shall meet customer requirements c The supplier shall assure that customer requirements have been met
This SAE Aerospace Standard (AS) establishes the requirements for fluid fittings that combine both beaded hose connections and pipe threaded connections for use in all types of fluid systems.
This SAE Aerospace Information Report (AIR) covers the generation of used phosphate ester aviation hydraulic fluid (AS1241) that is deemed waste because it does not meet in-service limits for use in aircraft. This document also lists the relevant United States Environmental Protection Agency (U.S. EPA) regulations on used hydraulic fluid that are in force at the time of this report's publication. Regulations of other countries as well as those for states and municipalities should be consulted prior to initiating any of the waste disposal recommendations listed here.
This document establishes training guidelines applicable to fiber optic fabricator technical training for individuals involved in the manufacturing, installation, support, integration and testing of fiber optic systems. Applicable personnel include: Managers Engineers Technicians Trainers/Instructors Third Party Maintenance Agencies Quality Assurance Production
This SAE Recommended Practice is part of the SAE J2534-2/X_0500 set of documents that extends the SAE J2534-1_0500 API (version 05.00) specification, and defines how to implement ethernet NDIS within the SAE J2534 API framework. This document details only the changes from SAE J2534-1_0500 and items not specifically detailed in this document are assumed to have not changed. An SAE J2534-2/9_0500 interface shall be compliant to the ethernet NDIS feature only when all the required functionality in this Recommended Practice is implemented. Any functionality not required for compliance will be specifically marked as “optional” in this document. This document must be used in conjunction with the SAE J2534-2/BA_0500 and J2534-2/RE_0500 documents.
Items per page:
50
1 – 50 of 221567