Results
This classification system tabulates the properties of vulcanized rubber materials (natural rubber, reclaimed rubber, synthetic rubbers, alone or in combination) that are intended for, but not limited to, use in rubber products for automotive applications.
This SAE Standard specifies requirements for vulcanized rubbers in sheet form for use as standards in characterizing the effect of test liquids and service fluids. The appendices contain the standard reference elastomer formulas. The property changes of the SRE in contact with the indicated fluid under specified test conditions are the responsibility of the user. See 7.3 and Table 1. This standard is not designed to provide formulations of elastomeric product compositions for actual service.
This SAE Recommended Practice provides a system for marking thermoset rubber parts to designate the general type of material from which the part was fabricated.
This SAE Standard provides a system for specifying significant material properties of thermoplastic elastomers (TPEs) that are intended for, but not limited to, use in automotive applications. In all cases where provisions of this classification system would conflict with those of the detailed specifications for a particular product, the latter shall take precedence. This classification is based on SI units.
This procedure provides methods to determine the appropriate inertia values for all passenger cars and light trucks up to 4540 kg of GVWR. For the same vehicle application and axle (front or rear), different tests sections or brake applications may use different inertia values to reflect the duty-cycle and loading conditions indicated on the specific test.
SAE J2886 Design Review Based on Failure Modes (DRBFM) Recommended Practice is intended for Automotive and Non-Automotive applications. It describes the basic principles and processes of DRBFM including planning, preparation, change point FMEA, design reviews, decisions based on actions completed, and feedback loops to other processes, such as design, validation and process guidelines (Appendix B - DRBFM Process Map). The intent of each fundamental step of the DRBFM methodology is presented. It is intended for use by organizations whose product development processes currently (or intend to) use Failure Mode & Effects Analysis (FMEA) or DRBFM as a tool for assessing the potential risk and reliability of system elements (product or process) or as part of their product improvement processes. DRBFM is not intended to replace FMEA however, companies interested in adopting DRBFM will benefit from the focus on specific change points and supporting engineering decisions based on detailed
This SAE Standard was developed to provide a method for indicating the direction of engine rotation and numbering of engine cylinders. The document is intended for use in designing new engines to eliminate the differences which presently exist in industry.
This method is intended to define the continuous upper temperature limit (CUTL) of thermoplastic elastomers and thermoset rubber with durometer hardness <=90 Shore A, to oxidation or other degradation when exposed solely to hot air for an extended period of time.
This document provides a method/procedure for specifying the properties of vulcanized elastomeric materials (natural rubber or synthetic rubbers, alone or in combination) that are intended for, but not limited to, use in rubber products for automotive applications. This document covers materials that do not contain any re-use, recycled, or regrind materials unless otherwise agreed to by manufacturer and end user. The use of such materials, including maximum percent, must be specified using a “Z” suffix. This classification system covers thermoset High Consistency Elastomers (HCEs) only. Thermoplastic Elastomer (TPE) materials are classified using SAE J2558. Silicone Formed In Place Gasket (FIPG) systems such as Room Temperature Vulcanized (RTV) Silicones, and Liquid Silicone Rubber (LSR) systems are classified using ASTM F2468.
This FMEA standard describes potential failure mode and effects analysis in design (DFMEA), supplemental FMEA-MSR, and potential failure mode and effects analysis in manufacturing and assembly processes (PFMEA). It assists users in the identification and mitigation of risk by providing appropriate terms, requirements, rating charts, and worksheets. As a standard, this document contains requirements—”must”—and recommendations—”should”—to guide the user through the FMEA process. The FMEA process and documentation must comply with this standard as well as any corporate policy concerning this standard. Documented rationale and agreement with the customer are necessary for deviations in order to justify new work or changed methods during customer or third-party audit reviews.
SAE J4001 provides instruction for evaluating levels of compliance to SAE J4000. Component text (Sections 4 to 9) from SAE J4000 is included for convenience during the evaluation process. Applicable definitions and references are contained in SAE J4000. SAE J4000 tests lean implementation within a manufacturing organization and includes those areas of direct overlap with the organization’s suppliers and customers. If applied to each consecutive organizational link, an enterprise level evaluation can be made. SAE J4001 relates the following approximate topic percentages to the implementation process as a whole: SAE J4001 is to be applied on a specific component basis. Each of the 52 components tests part of, one, or multiples of the specific requirements of lean implementation. Implementation throughout an organization may be measured by evaluating all of the components. The level of compliance for each component relative to best practice may be used as a reference by an organization to
AS22759 specification covers fluoropolymer-insulated single conductor electrical wires made with tin-coated, silver-coated, or nickel-coated conductors of copper or copper alloy as specified in the applicable detail specification. The fluoropolymer insulation may be polytetrafluoroethylene (PTFE), fluorinated ethylene propylene (FEP), polyvinylidene fluoride (PVF2), ethylene-tetrafluoroethylene copolymer (ETFE), or other Fluoropolymer resin. The fluoropolymer may be used alone or in combination with other insulation materials. These abbreviations shall be used herein. When a wire is referenced herein, it means an insulated conductor (see 7.7).
This document covers the requirements for insulated, single-conductor, electric wires with tin-coated, silver-coated, or nickel-coated conductors of copper or copper alloy as specified in an applicable generated performance sheet (see Appendix A for sample). It provides general performance requirements, ratings, and information for various characteristics of insulated wire systems used in aerospace applications. Numerical test requirements, or parameters, were originally developed using either English or metric units. The original, primary, units are shown first with the secondary (converted) units in parentheses. Secondary units are listed for information only and are not to be considered requirements. Wire will be assigned a level of performance for many requirements set forth in this standard. These performance levels, in addition to numerical test results, shall be listed in the applicable performance sheet. This standard contains some tests and referenced AS4373 Test Methods that
The “Model Architecture and Interfaces Recommended Practice for Ground Vehicle System and Subsystem Dynamical Simulation” defines the architectural structure of a ground vehicle system dynamical model by partitioning it into subsystem models and by defining subsystem interfaces required to enable plug-and-play operation of a dynamical simulation models. All types of ground vehicle were considered in the development of the architecture, such as, passenger cars, light and medium duty trucks, heavy duty tractor trailer trucks, and vehicles/equipment for military, farming, construction, and mining. Versatility of this architectural partitioning is demonstrated by showing how it can be applied to different vehicle configurations. Application examples of architecture are provided for a large number of the publicly known ground vehicle configurations in production, testing, or development. This recommended practice encompasses standards to enable seamless plug-and-play reusability of
This specification establishes the requirements for various types of identification sleeving that will shrink to a predetermined size upon the application of heat after it has been marked. Continuous operating temperature ratings range from -55° to 175°C (-67° to 347°F). (See 6.1).
This SAE Recommended Practice is intended to establish a procedure to certify the fundamental driving skill levels of professional drivers. This certification can be used by the individual driver to qualify their skills when seeking employment or other professional activity. These certification levels may also be used by test facilities or other organizations when seeking test or professional drivers of various skills. The associated family of documents listed below establish driving skill criteria for various specific categories. SAE J3300: Driving level SAE J3300/1: Low mu/winter driving SAE J3300/2: Trailer towing SAE J3300/3: Automated driving Additional certifications to be added as appropriate. This main document provides: (1) common definitions and general guidance for using this family of documents, (2) directions for obtaining certification through Probitas Authentication®1, and (3) driving level examination requirements.
This SAE Recommended Practice defines the minimum functional requirements for quick connect couplings used for supply, return, and vapor/emission fuel system connections. This document also defines standard male tube end form dimensions, so as to guarantee interchangeability between all connector designs of the same male tube end form size. This document applies to automotive and light truck applications under the following conditions: a Gasoline and diesel fuel delivery systems or their vapor venting or evaporative emission control systems. b Operating pressure up to 500 kPa, 5 bar, (72 psig). c Operating vacuum down to −50 kPa, −0.5 bar (−7.2 psi). d Operating temperatures from −40 °C (−40 °F) to 115 °C (239 °F). Quick connect couplings function by joining the connector to a mating tube end form, then pulling back to assure a complete connection. The requirements stated in this document apply to new connectors in assembly operations unless otherwise indicated. For service operations
Items per page:
50
1 – 50 of 211741