Results
This document defines the test procedures and performance limits of steady state and transient voltage characteristics for 12 V, 24 V, or 48 V electrical power generating systems used in commercial ground vehicles.
This SAE Recommended Practice was developed primarily for passenger car and truck applications but may be used in marine, industrial, and similar applications. It addresses nonmetallic caps and both metallic and nonmetallic filler necks.
This procurement specification covers aircraft-quality solid rivets and tubular end rivets made from a corrosion- and heat-resistant nickel alloy of the type identified under the Unified Numbering System as UNS N06002.
This standard applies to all products and services produced for Aeronautics and Space enterprises and regulatory environments, including those produced by component facilities and technical and service support centers. If applied, this standard must be cited in the CM requirements of Enterprise Planning, Facilities Programs, Projects, and Supplier agreements. This standard applies throughout all phases of the program and project life cycle. CM is about the truth, trust, and traceability of products, data used to produce products, and processes throughout their life cycle and should be applied across the Enterprise at the process and product level. The significant data to which CM is applied includes scientific and engineering data; data that drives mission success; data that ensures IT security; and data used to make technical, programmatic, and business decisions. Proper application of CM is essential for product integrity and overall effectiveness. Acquirers complying with the
This SAE Standard includes names of major components and parts particular to this type of machine.
This SAE Recommended Practice establishes uniform test procedures for friction based parking brake components used in conjunction with hydraulic service braked vehicles with a gross vehicle weight rating greater than 4500 kg (10 000 lb). The components covered in this document are the primary actuation and the foundation park brake. Various peripheral devices such as application dashboard switches or indicators are not included. These test procedures include the following: a Brake Related Tests 1 Brake Functional Performance 2 Brake Dynamic Torque Performance 3 Brake Corrosion Resistance 4 Brake Endurance with Torque 5 Brake Endurance without Torque 6 Vibration Resistance 7 Brake Ultimate Static Load 8 Brake Lining Wear Adjuster Function b Actuation Related Tests 1 Mechanical Actuator Functional Performance 2 Mechanical Actuator Endurance 3 Mechanical Actuator Quick Release 4 Mechanical Actuator Ultimate Load 5 Spring Apply Actuator Functional Performance 6 Spring Apply Actuator
This test can be used to evaluate odor characteristics of non-metallic materials used in the interior cabin of a vehicle. The test conditions, odor panel requirements, scale for odor intensity and reporting of results are specified. The data from this test are useful when compared to data obtained from samples with known odor characteristics.
This SAE Recommended Practice is intended to cover plastic safety glazing for use in motor vehicles and motor vehicle equipment. Nominal specifications for thickness, flatness, curvature, size, and fabrication details are presented principally for the guidance of body engineers and designers. For additional information on plastic safety glazing materials for use in motor vehicles and motor vehicle equipment, please refer to SAE J673.
This specification covers a corrosion-resistant steel in the form of wire.
This SAE Standard was developed to provide a method for indicating the direction of engine rotation and numbering of engine cylinders. The document is intended for use in designing new engines to eliminate the differences which presently exist in industry.
This specification covers a premium aircraft-quality, high-alloy tool steel gas-atomized and HIP consolidated in the form of bars, wire, forgings, and forging stock.
This SAE Standard specifies the essential interface dimensions, the installation dimensions, and the operating requirements for hydraulic couplers employed to transmit hydraulic power from agricultural tractors to agricultural implements and farmstead equipment as defined in SAE J1150.
Most signal and marking lighting devices have light sources (bulbs), which can be based on either filament or LED technology. To assure field replacement, it is important that light source types employed be readily available in normal service channels. This document defines the physical, electrical, and photometric characteristics necessary to achieve a proper replacement for popular types of signal and marking light sources. Some of the design characteristics in this document are listed solely for the sake of standardization and are not intended to describe the performance of lighting devices (lamp assemblies) on the vehicle. Halogen filament light sources suitable for signal and marking lighting are specified in SAE J2560.
This SAE Standard for reliability-centered maintenance (RCM) is intended for use by any organization that has or makes use of physical assets or systems that it wishes to manage responsibly.
This procurement specification covers aircraft quality solid rivets and tubular end rivets made from a corrosion-resistant steel of the type identified under the Unified Numbering System as UNS S30200.
This code provides a test procedure for obtaining and determining extremely high brake fluid temperature encountered in the brake system of a vehicle that is equipped with disc brakes. Vehicles in normal operation may or may not produce brake fluid temperatures that are obtained in this procedure.
The intention of this standard is to establish a framework to measure the efficiency of PWM HVAC Blower Controllers and Brushless DC Motor Controllers and define a usage based overall efficiency. This result can then be used by vehicle OEMs to demonstrate compliance towards requirements or benchmarks established by regulatory agencies.
This Aerospace Standard covers all automatic pressure altitude code generating equipment manufactured under this standard and complying with the requirements specified herein up to the maximum range of pressure altitude as indicated on the equipment nameplate. In those cases where the code generating equipment forms part of an aircraft system, such as a pressure altimeter, an air data computer or an ATC Transponder, this standard applies only to the code generating equipment as defined in paragraph 1.2.
This SAE Aerospace Standard (AS) specifies solid polytetrafluoroethylene (PTFE) retainers (backup rings) for use in static glands in accordance with AS5857. They are usually for use in hydraulic and pneumatic systems as anti-extrusion devices in conjunction with O-rings and other seals.
This specification establishes requirements for automatic shutoff, quick-disconnect coupling assemblies for fuel and oil lines.
This aerospace specification defines the requirements for a threadless, flexible, conductive, self-bonding coupling assembly which, when installed on fixed cavity ferrules, provides a flexible, current carrying connection for joining tubing and components in aircraft fuel, vent and other systems. The assembled coupling is designed to provide interchangeability of parts and components between qualified manufacturers for the service life of the aircraft system. The assembled coupling is for use from -65 to +200 °F at nominal operating pressures (125 psig for -08 through -64 and 30 psig for -72 through -88). This aerospace specification is a departure from prior qualification practices for assembled couplings. Prior practice sought to validate this type of assembled coupling design by conducting a sequence of tests on sets of coupling assemblies. There were multiple test sequences and each was conducted on a different set of coupling assemblies. Each of these test sequences challenged a
This document is limited to the aerospace industry, where an approved manufacturer requests a supplier to ship an article against the approved manufacturer’s quality system directly to a customer. The direct ship process is not required or applicable to standard parts or military parts. In this process, the approved manufacturer is responsible for assurance that the article conforms to type design information.
This SAE Recommended Practice applies to speedometers, odometers, and speedometer drives typical of passenger vehicles, buses, and trucks used for personal or commercial purposes. The method of determining wheel revolutions per unit distance (3.1) and overall system design variation (3.3.3) are applicable to passenger cars only. Comparable recommendations for trucks and buses are under development. The data of tachometers is applicable to vehicular use, as previously described, and also to stationary and marine engines and special vehicles.
This SAE Recommended Practice is intended for hubs and spoke wheels used on Class 6, 7, and 8 truck/truck-tractor non-powered front axles, powered and non-powered rear axles and trailer axles, for which bearing setting is manually adjusted. Assemblies using spacers to control bearing preload and endplay may differ in geometry and bearing componentry.
This document establishes training guidelines applicable to fiber optic quality assurance technical training for individuals involved in the manufacturing, installation, support, integration and testing of fiber optic systems. Applicable personnel include: Managers Engineers Technicians Trainers/Instructors Third Party Maintenance Agencies Quality Assurance Production
This SAE Standard defines a method for evaluating the immunity of automotive electrical/electronic devices to radiated electromagnetic fields coupled to the vehicle wiring harness. The method, called bulk current injection (BCI), uses a current probe to inject RF onto the wiring harness in the frequency range of 1 to 400 MHz. BCI is one of a number of test methods that can be used to simulate the electromagnetic field. The test method refers to ISO 11452-4 (please refer to ISO 11452-4 for test procedures). In addition to ISO 11452-4, this test method also includes a differential bulk current injection (DBCI) test. DBCI is described in Section 4 of this document.