Results
This test method provides a procedure for measuring no-load rotational breakaway torque of self-lubricating spherical bearings.
The primary objective of this recommended practice is to confirm that vehicles can communicate a minimum set of information in accordance with diagnostic test services specified in SAE J1979-2, or the equivalent ISO 14229-1:2013 (Ed. 2) and SAE J1979-3 documents. A successful result using the SAE J1699-5 Automotive Alliance for Innovation (AAI) software for OBD-II testing indicates that the main aspects of UDS communication have been examined, but it does not provide assurance of complete compliance with all aspects of SAE J1979-2 or SAE J1979-3. SAE J1699-5 tests run with a SAE J2534 device hardware and API that is not fully compliant will result in a test failure. This specification takes precedence over all conflicts in the documents cited in this section.
This SAE Information Report provides SAE’s recommendations for meeting the requirements for Real Emissions Assessment Logging (REAL) oxides of nitrogen (NOx) accuracy demonstration and for the implementation of REAL NOx binning requirements as defined in onboard diagnostics (OBD) regulations 13 CCR 1971.1 and 13 CCR 1968.2.
This SAE Aerospace Information Report (AIR) describes procedures for use in the field to determine if 115/200 Volt, 400 Hz aircraft external electrical power connectors are excessively worn, which may result in the inability of the external power plug to be retained, intermittent electrical performance, and arcing.
This SAE Information Report establishes a uniform procedure for assuring the manufactured quality, installed utility, and performance of automotive remote steering controls other than those provided by the vehicle manufacturer (OEM). These products are intended to provide driving capability to persons with physical disabilities. The adaptive modifications seek to compensate for lost or reduced function in the extremities of the driver with a disability. Remote steering controls are designed to provide a steering input device alternative to the OEM steering wheel that either reduces the required input force, changes the required range of motion or changes the location of the steering control, or any combination of the above. These controls supplement by power, other than by the driver’s own muscular efforts, the force output of the driver with a disability. Because this is an Information Report, the numerical values for performance measurements presented in this report and in the
This specification covers a corrosion- and heat-resistant nickel alloy in the form of plate nominally 2.00 inches (50.8 mm) and under in thickness, inclusive.
This SAE Recommended Practice sets forth a method by which the turning ability and off tracking of motor vehicles can be determined.
This SAE Aerospace Standard (AS) establishes minimum requirements for eddy current inspection of circular holes in nonferrous, metallic, low conductivity (less than 5% IACS) aircraft engine hardware with fasteners removed. The inspection is intended to be performed at maintenance and overhaul facilities on engine run hardware.
This SAE Recommended Practice describes the recommended methods for testing flexible harness coverings for use on ground vehicle electrical distribution systems. It shall apply to all tapes, extruded tube, and textile tube.
This SAE Metric Aerospace Standard (MA) establishes the requirements for fluid fittings that combine both weld fitting end and 24° cone flareless fitting end connections for use in all types of metric fluid systems.
This procedure applies to directional control valves or other valves which in various positions direct or block fluid flow as applied to Off-Road Self-Propelled Work Machines as referenced in SAE J1116.
This SAE Aerospace Information Report (AIR) provides basic information on the use of slipper seal sealing devices when used as piston (OD) and rod (ID) seals in aerospace fluid power components such as actuators, valves, and swivel joints, including: The definition of a slipper seal and the description of the basic types in use. Guidelines for selecting the type of slipper seal for a given design requirement are provided in terms of friction, leakage, service life, installation characteristics, and interchangeability.
This SAE Standard was developed to provide a method for indicating the direction of engine rotation and numbering of engine cylinders. The document is intended for use in designing new engines to eliminate the differences which presently exist in industry.
The following schematic diagrams reflect various methods of illustrating automotive transmission arrangements. These have been developed to facilitate a clear understanding of the functional interrelations of the gearing, clutches, hydrodynamic drive unit, and other transmission components. Two variations of transmission diagrams are used: in neutral (clutches not applied) and in gear. For illustrative purposes, some typical transmissions are shown.
This specification covers a tin bronze in the form of sand and centrifugal castings (see 8.5).
The scope of this SAE Recommended Practice is restricted to the testing of original equipment on passenger vehicles and to provide for a uniform industry test procedure.
This SAE Recommended Practice is part of the SAE J2534-2/X_0500 set of documents that extends the SAE J2534-1_0500 API (version 05.00) specification. It defines the common data structures and constants that will be used to implement the extension to the SAE J2534 API. This document will only include the items that are used by the V05.00 API and that are NOT included in SAE J2534-1_0500. It will not include items from older API versions unless they are used by the V05.00 API.
This specification covers an aluminum alloy in the form of sheet.
This specification and its supplementary detail specifications cover para-aramid materials in the form of thread.
This specification covers a low-alloy steel in the form of welding wire.
This interface standard applies to fuzes/fuzing systems (referred to as fuzing system hereafter) in airborne weapons that use a MIL-STD-1760 type interface. It defines the powers, the discrete signals and the serial data interface for the communications at the interface between the fuzing system and the remainder of the weapon, including the weapon control unit. The Class 1 interface is an electrical only interface that facilitates use of MIL-STD-1760 type platform store interfaces for the fuze to monitor intentional release and defines the fuze interface bus communications protocol to allow sending and receiving data from fuzing systems. Class 2 interfaces add a defined connector and additional interfaces to facilitate the exchange of compatible fuzing systems. Class 3 interfaces add further interface definitions to facilitate the exchange of AS5680A compatible fuzing systems components. The bus communications protocol provides a means by which the weapon may set mission parameters
This SAE Recommended Practice is part of the SAE J2534-2/X_0500 set of documents that extends the SAE J2534-1_0500 API (version 05.00) specification, and defines how to implement fault-tolerant CAN (FT CAN) within the SAE J2534 API framework. This document details only the changes from SAE J2534-1_0500 and items not specifically detailed in this document are assumed to have not changed. An SAE J2534-2/8_0500 interface shall be compliant to fault-tolerant CAN (FT CAN) feature only when all the required functionality in this SAE Recommended Practice is implemented. Any functionality not required for compliance will be specifically marked as “optional” in this document. This document must be used in conjunction with the SAE J2534-2/BA_0500 and SAE J2534-2/RE_0500 documents.
SAE J1978-1 specifies a complementary set of functions to be provided by an OBD-II scan tool. These functions provide complete, efficient, and safe access to all regulated OBD (on-board diagnostic) services on any vehicle which complies to SAE J1979. The content of this document is intended to satisfy the requirements of an OBD-II scan tool as required by current U.S. OBD regulations. This document specifies: A means of establishing communications between an OBD-equipped vehicle and an OBD-II scan tool. A set of diagnostic services to be provided by an OBD-II scan tool in order to exercise the services defined in SAE J1979. In addition, SAE J1978-1 covers first generation protocol functionality defined in SAE J1979 plus automatic protocol determination for all SAE J1979/J1979-2/J1979-3 application content. The presentation of the SAE J1978 document family, where SAE J1978-1 covers first generation protocol functionality defined in SAE J1979 and protocol determination for SAE J1979, SAE
This SAE Standard applies to lead-acid 12 V heavy-duty storage batteries as described in SAE J537 and SAE J930 for uses in starting, lighting, and ignition (SLI) applications on motor vehicles and/or off-road machines. These applications have some of the following characteristics: High levels of power are required to start the vehicle’s internal combustion engine. The need to supply this power limits the maximum depth of discharge to a fraction of the total capacity of the battery. The battery must be maintained at a charge level sufficient to perform this primary function by the vehicle’s voltage-regulated charging system. The vehicle’s engine powers a voltage-regulated charging system that limits the charging voltage when spinning at sufficient speed and when total loads do not exceed its output limits. The battery is subject to deeper discharging than a typical automotive application as a result of the following conditions: High daily hours of use High numbers of starts per day
This standard covers the operational characteristics, environment, durability procedures, and test procedures for in-tank electric fuel pumps for automotive gasoline applications. Specific performance and test criteria used in conjunction with this procedure are specified on the pump drawing. Particular sections of this document may be required for all applications. This standard is intended to evaluate specific characteristics as a supplement to normal material inspections, dimensional checking, and in-process controls, and should in no way adversely influence other inspection operations.
A tested method of data presentation and use is described herein. The method shown is a useful guide, to be used with care and to be improved with use.
Items per page:
50
1 – 50 of 222741