Results
This AIR provides information about the specific requirements for missile hydraulic pumps and their associated power sources.
This specification covers piston rings fabricated from cast iron.
This document provides vehicle-level data collection, data analysis, and data verification procedures that may be used to verify that an instrument under test (IUT) satisfies the vehicle-level requirements specified in the SAE International (SAE) J2945/1 standard. For the purposes of this recommended practice, “vehicle-level requirements” primarily consist of those requirements which can be verified external to the vehicle. The IUT for these procedures is a configured dedicated short range communications (DSRC) vehicle-to-vehicle (V2V) device as defined in SAE J2945/1 and is installed on a light vehicle. While the IUT is conceptually separated from the vehicle it is installed on, the tests outlined in this document are primarily vehicle-level so the terms “vehicle” and “IUT” can generally be considered interchangeable. Additionally, non-vehicle-level complementary tests, not included in this document, are required to verify that the entire set of requirements specified in SAE J2945/1
This SAE Recommended Practice provides a system for marking thermoset rubber parts to designate the general type of material from which the part was fabricated.
This specification covers crimp-style aluminum lug terminals and conductor splices for aluminum aircraft wire. Lug terminals and conductor splices are hereafter called “terminals.”
This specification establishes the requirements for anodic coatings on aluminum alloys.
This SAE Aerospace Standard (AS) establishes the general requirements for a miniature probe type self-sealing, self-aligning, non-locking coupling intended for aerospace liquid cooling systems. The AS5072/slash sheets define the specific performance and dimensional requirements.
This SAE Standard was developed to provide a method for indicating the direction of engine rotation and numbering of engine cylinders. The document is intended for use in designing new engines to eliminate the differences which presently exist in industry.
This specification covers a magnesium alloy in the form of extruded bars, rods, wire, tubing, and profiles.
This SAE Standard specifies dimensional characteristics of flat blades of single-pole connectors and specific requirements for on-board electrical harnesses of road vehicles, which can be fitted into female connectors such as those given as in Appendix A. This document applies to connectors designed to be disconnected after mounting in the vehicle in the case of repair and/or maintenance only.
This Standard covers Bank and Pitch Instruments which measure and display the angular displacement of bank and pitch from a gyroscopic vertical reference. This reference may be pneumatically or electrically driven and be contained within the instrument display case or located remotely. Unless otherwise specified, whenever the term "Instrument" is used, it is to be understood to be the complete system of gyro component, any auxiliary equipment and display.
The task of chemical process operator in the parts cleaning area is generally considered unskilled labor and in the past, little or no training had been provided or recommended. Since overhaul cleaning is a critical process step prior to visual and fluorescent penetrant inspection processes, consideration must be given to minimum levels of training for these process operators. It is the responsibility of the department supervisor to ensure that all personnel within the department are trained to acceptable level in all general aspects of health and safety and basic operating procedures. This document is intended to augment the local quality control system which will control the application and frequency of the guidelines stated within.
This SAE Aerospace Recommended Practice (ARP) recommends criteria for an Electronic Data Management System (EDMS) for use on the flight deck of transport aircraft. The EDMS may be the primary, and in some cases sole, on board source of documentation and information for flight operations, engineering, aircraft maintenance, cabin services, and training. This document addresses flight operations applications only. It addresses the requirements for the flight deck characteristics of airborne equipment elements for an Electronic Data Management System (EDMS), but not the ground support system requirements. Development of ground support systems for EDMS will be a significant task, which must take account of the end-user information handing requirements specified here. An Electronic Library System (ELS) is a partial implementation of EDMS, which incorporates only the data storage, retrieval and display functions. The appropriate aspects of this document are applicable to Electronic Library
This SAE Aerospace Recommended Practice (ARP) applies to survival kits to be carried with life rafts or slide/rafts on transport category airplanes flying extended over-water routes and equipped with approved satellite alerting devices (e.g., 406 MHz Emergency Locator Transmitter [ELT]), available for deployment after an emergency landing.
This SAE Recommended Practice describes the test procedures for conducting frontal impact occupant restraint and equipment mounting integrity tests for ambulance patient compartment applications. Its purpose is to describe crash pulse characteristics and establish recommended test procedures that will standardize restraint system and equipment mounting testing for ambulances. Descriptions of the test set-up, test instrumentation, photographic/video coverage, and the test fixtures are included.
This standard establishes processes for performing and documenting mitigation steps taken to reduce the harmful effects of tin whiskers in electronic systems for ADHP applications. This includes electronic piece parts and mechanical hardware that are used on or in the proximity of electronics. This document identifies the requirements for mitigating the effects of tin whiskers applicable to the requirements of the SAE GEIA-STD-0005-1 Lead-free Control Plan (LFCP). An LFCP documents the specific Pb-free materials and assembly processes the LFCP owner will use to eliminate or mitigate the Pb-free risks to assure customers that their ADHP soldered electronic products will meet the applicable reliability requirements of the customer. This standard may also be used independently of SAE GEIA-STD-0005-1.
The purpose of this recommended practice is to establish a standard format for the presentation of helicopter mission data, which will provide data required to establish airframe and/or engine component life.
This document recommends criteria for electronic displays on the flight deck of transport aircraft. Electronic displays include electronic flight instruments, alert displays, aircraft system displays and control/display units for flight management and radio management systems.
This test method outlines a standard procedure for performing cyclic reversing load testing on oscillating sliding bearings. The wear data from these tests is to be used for qualification requirements and to establish bearing design criteria.
This Aerospace Standard covers two basic Stall Warning Systems, one measures air flow and pressure distribution on the airfoil and the other measures the angle of airflow with respect to an arbitrary reference line. Each type of system includes, as a minimum, a sensor and the means for activating a device which warns the pilot of an impending stall.
This SAE Aerospace Information Report provides a general discussion on gaseous breathing oxygen and oxygen equipment for use on commercial aircraft. Other types of oxygen systems are mentioned to assist in this discussion. For detailed information on systems other than gaseous, refer to the appropriate section of AIR825.
This SAE Aerospace Recommended Practice (ARP) recommends criteria for the design and installation of Head-Up Display (HUD) systems. The recommendations are applicable to HUD systems for transport category aircraft, which display flight information (focused at infinity) in the forward field of view. The HUD total system requirement recommendations shall primarily lead to certifiable fail-passive CAT III characteristics and performance. This document forms a part of these recommendations. This document does not address devices for peripheral vision of displays worn by the pilot, nor the presentation of Enhanced Vision System (EVS) information.
The Class A Task Force of the Vehicle Network for Multiplex and Data Communications Committee is publishing this SAE Information Report to provide insight into Class A Multiplexing. Multiplexed actuators are generally defined as devices which accept information from the multiplexed bus. A multiplexed actuator can be an output device controlled by the operator or an intelligent controller. A Multiplex actuator can also be a display device that reports the status of a monitored vehicle function. This document is intended to help the network system engineers and is meant to stimulate the design thought process. A list of multiplexed actuator examples is provided in Appendix A, Figure A1. Many other examples can be it identified.
This specification covers a copper-beryllium alloy in the form of bars and rods up to 3.000 inches (76.20 mm), inclusive, in nominal diameter or least distance between parallel sides (see 8.7).
This specification, in conjunction with the general requirements covered in AMS2431 establishes the requirements for glass shot to be used for peening of metal parts.
Items per page:
50
1 – 50 of 215848