Authors Abstract
Content
The effect of eight installation and component parameters on cooling system heat rejection and air flow were examined in detail in a wind tunnel facility. A quarter-replicate, two level factorial test plan was followed. Within the ranges of each parameter tested, the fan characteristics and the projection of fan into the shroud are highly significant parameters. The fan to radiator distance, the radiator characteristics, and the fan tip to shroud clearance are significant parameters. The fan to engine block distance and the type of shroud are not significant parameters.