Water Jacket Spacer for Improvement of Cylinder Bore Temperature Distribution

2005-01-1156

04/11/2005

Event
SAE 2005 World Congress & Exhibition
Authors Abstract
Content
For reduction of fuel consumption, a new device “Water Jacket Spacer” which improves temperature distribution of a cylinder block bore wall was developed. In the case of a conventional cylinder block, coolant flow concentrates at the bottom and middle region of the water jacket. While temperature of the upper bore wall is high (due to high-temperature combustion gas) the temperature of the lower bore wall is low, since its only function is to support the piston. When the developed spacer is inserted into a water jacket, the coolant flow concentrates at the upper part of the jacket. As a result, cooling ability to the upper bore wall was improved and temperature of lower bore wall was increased, thereby reducing fuel consumption.
Meta TagsDetails
DOI
https://doi.org/10.4271/2005-01-1156
Pages
7
Citation
Matsutani, T., Nakada, T., Shinpo, Y., and Hatano, M., "Water Jacket Spacer for Improvement of Cylinder Bore Temperature Distribution," SAE Technical Paper 2005-01-1156, 2005, https://doi.org/10.4271/2005-01-1156.
Additional Details
Publisher
Published
Apr 11, 2005
Product Code
2005-01-1156
Content Type
Technical Paper
Language
English