Track De-icing and Road Maintenance Method Based on Induction Heating Technology
2026-99-1536
9/11/2026
- Content
- In order to solve the problems of long preheating time and high energy consumption caused by the traditional resistance heating track deicing technology and large power supply load, this paper presents a track deicing and road maintenance method based on electromagnetic induction heating. This paper studies the operational bottlenecks of the resistance heating system in a certain marshalling yard. It explains the eddy current heating from the principle of electromagnetic induction heating and designs an appropriate coil for turnouts and derives its power calculation formula. A mathematical model for the 'solid-liquid' phase transformation in the melting of snow is created and the melting parameter α = 0.623. In comparative experiments, compared to a 4kW electromagnetic induction heating device with no preheating time which melts snow up to 5cm in 40 minutes and consumes 40kW · h of energy in 1 hour, a 13kW resistance heating device needs 150 minutes to preheat, 180 minutes to melt, and consumes 130kW · h of energy. Use 70% less energy and help with track and road de-icing and upkeep with this technology.
- Citation
- Song, Z., Li, Z., Wei, D., Yang, J., et al., "Track De-icing and Road Maintenance Method Based on Induction Heating Technology," 2025 5th International Conference on Logistics System, Traffic and Transportation, Dalian, China, December 5, 2025, https://doi.org/10.4271/2026-99-1536.