Time-resolved Chemical Analysis by Laser Mass Spectrometry: Monitoring of In-Cylinder and Catalytic-Converter Processes of Combustion Engines

2005-01-0679

04/11/2005

Event
SAE 2005 World Congress & Exhibition
Authors Abstract
Content
A laser mass spectrometer (LAMS) for simultaneous detection of NO, NO2, NH3 and other components (N2O, CO, O2, H2O, aromatics) in the exhaust of combustion engines is presented. Its temporal resolution is in the 10 ms range. Comparison with non-dispersive IR, flame ionisation detection and chemical luminescence detection have been performed. Emissions of Otto and Diesel engines have been studied at different velocities, load and three sampling positions: in front of a catalytic pre-converter, in front and after the main catalytic converter. Finally, NO, CO, H2O, toluene and O2 were detected within the cylinder in dependence on the crank angle with a time resolution in the 10 ms range.
Meta TagsDetails
DOI
https://doi.org/10.4271/2005-01-0679
Pages
12
Citation
Boesl, U., Weishäupl, R., Thiel, W., Püffel, P. et al., "Time-resolved Chemical Analysis by Laser Mass Spectrometry: Monitoring of In-Cylinder and Catalytic-Converter Processes of Combustion Engines," SAE Technical Paper 2005-01-0679, 2005, https://doi.org/10.4271/2005-01-0679.
Additional Details
Publisher
Published
Apr 11, 2005
Product Code
2005-01-0679
Content Type
Technical Paper
Language
English