Thermal Vacuum Tests of Olympus Heat Pipe Radiators

851363

07/01/1985

Event
Intersociety Conference on Environmental Systems
Authors Abstract
Content
The results of the thermal tests performed on the OLYMPUS Large Telecommunication Satellite Heat Pipe Radiators are presented. The test set-up maintained the Heat Pipes horizontal, the dissipation and thermal characteristics of electronic units being simulated by thermal dummies. The tests were divided in three phases with different temperatures of the chamber cryogenic shrouds to simulate the worst steady (equinox) cold case and investigate a fictitious extreme cold case (end of eclipse steady state) and an equivalent hot case. The results testify the adequacy of the Radiator design and the agreement between analytical predictions and temperatures measured during the test.
Meta TagsDetails
DOI
https://doi.org/10.4271/851363
Pages
12
Citation
Boggiatto, D., Colizzi, E., Perotto, V., and Tavera, S., "Thermal Vacuum Tests of Olympus Heat Pipe Radiators," SAE Technical Paper 851363, 1985, https://doi.org/10.4271/851363.