Thermal Distortion Analysis for the Coronal Diagnostic Spectrometer

951700

07/01/1995

Event
International Conference on Environmental Systems
Authors Abstract
Content
The Coronal Diagnostic Spectrometer (CDS) has a pointing requirement of 2 arcseconds, which corresponds to a thermal gradient restriction of 2°C across the optical bench. This paper shows the effect of a transient thermal environment on the pointing performance of the CDS optical bench in terms of thermally induced alignment errors of the optical components. Thermal analysis provides the temperature profiles of the optical bench as a function of various heater scenarios which serve as the load sets for the steady state, non-linear analyses, the results of which are nodal displacements and rotations.
Meta Tags
Topics
Affiliated or Co-Author
Details
DOI
https://doi.org/10.4271/951700
Pages
7
Citation
Moss, R., and Gabriel, S., "Thermal Distortion Analysis for the Coronal Diagnostic Spectrometer," SAE Technical Paper 951700, 1995, https://doi.org/10.4271/951700.
Additional Details
Publisher
Published
Jul 1, 1995
Product Code
951700
Content Type
Technical Paper
Language
English