Thermal Conditioning Unit
941284
6/1/1994
- Content
- This document describes a Thermal Conditioning Unit (TCU) concept that can be used to keep samples at any selected temperature between -20 °C and 50 °C in space environment.The adaptation to the two mission scenarios (Biorack in Spacelab IML-2 and MIR station) where the concept has been used is described, providing design solutions, performances and test results.Proposals for new future configurations are also presented.Safety and reliability aspects are assessed.
- Citation
- Madorell, X., Llamas, X., Pastor, M., and Tomás, A., "Thermal Conditioning Unit," International Conference On Environmental Systems, Friedrichshafen, Germany, June 20, 1994, https://doi.org/10.4271/941284.