Test and Analysis of Composite Hat Stringer Pull off Test Specimens

VFS-F52-1174

6/4/1996

Authors
Abstract
Content

Hat stringer pull off tests were performed to evaluate the delamination failure mechanisms in the flange region for a rod-reinforced composite hat stringer section. A special test fixture was used to pull the hat off the stringer while reacting the pull off load through roller supports at both stringer flanges. Microscopic examinations of the failed specimens revealed that failure occurred at the ply termination in the flange area where the skin thickness is built up by adding 45/-45 tape plies on the top surface. Test results indicated that the as-manufactured microstructure in the flange region has a strong influence on the delamination initiation and the associated pull off loads. Finite element models were created for each specimen with a detailed mesh based on micrographs of the critical location. A fracture mechanics approach and a mixed mode delamination criteria were used to predict the onset of delamination and the pull off load. By modeling the critical local details of each specimen from micrographs, the model was able to accurately predict the hat stringer pull off loads and replicate the scatter in the test results.

Meta TagsDetails
DOI
https://doi.org/10.4050/VFS-F52-1174
Citation
Rousseau, C., Li, J., and O'Brien, T., "Test and Analysis of Composite Hat Stringer Pull off Test Specimens," Forum 52 - Washington, DC 1996, Washington, DC, June 4, 1996, https://doi.org/10.4050/VFS-F52-1174.
Additional Details
Publisher
Published
6/4/1996
Product Code
VFS-F52-1174
Content Type
Technical Paper
Language
English