Solid Polymer Electrolysis Oxygen Generator Testing at MSFC

961518

07/01/1996

Event
International Conference On Environmental Systems
Authors Abstract
Content
The International Space Station (ISS) redesign made operational and interface requirements changes to the previous Space Station Freedom baseline. These changes include Oxygen Generation Assembly (OGA) production only on the daylight side of each orbit; nitrogen interface pressure reduction to 100 +/- 10 psia (690 +/- 69 kPa); and available production rates of nominal, nominal +10%, and nominal -10%.
In 1994 a test program was initiated at MSFC to verify OGA capabilities for cyclic operation. The liquid feed solid polymer electrolyzer from the 1990 OGA Comparative Test was refurbished and modified as required. This paper describes the operation of the test unit, and presents a discussion of the test data and test results.
Meta TagsDetails
DOI
https://doi.org/10.4271/961518
Pages
8
Citation
Erickson, R., Roy, R., Mason, R., and Tatara, J., "Solid Polymer Electrolysis Oxygen Generator Testing at MSFC," SAE Technical Paper 961518, 1996, https://doi.org/10.4271/961518.
Additional Details
Publisher
Published
Jul 1, 1996
Product Code
961518
Content Type
Technical Paper
Language
English