Sampling Method for Particle Measurements of Vehicle Exhaust

2001-01-0219

03/05/2001

Event
SAE 2001 World Congress
Authors Abstract
Content
This paper describes a new sampling concept for particle emission measurements. The purpose is to produce repeatable and reproducible conditions for nucleation phenomena. The exhaust is sampled and instantaneously diluted by inserting a porous tube diluter inside the tailpipe. This is carried out in order to prevent uncontrolled sample transformations in sampling lines. The sampling system was tested in size distribution measurement of light duty diesel vehicle. The tests showed a clearly bimodal size distribution with distinguished nuclei and accumulation modes.
Meta TagsDetails
DOI
https://doi.org/10.4271/2001-01-0219
Pages
6
Citation
Mikkanen, P., Moisio, M., Keskinen, J., Ristimäki, J. et al., "Sampling Method for Particle Measurements of Vehicle Exhaust," SAE Technical Paper 2001-01-0219, 2001, https://doi.org/10.4271/2001-01-0219.