The Role of Suction Line Heat Exchanger in Transcritical R744 Mobile A/C Systems

1999-01-0583

03/01/1999

Event
International Congress & Exposition
Authors Abstract
Content
Transcritical R744 systems are under consideration for use in mobile air conditioning. Experimental results indicate that the inherent thermodynamic shortcomings of R744 could be overcome by exploiting inherent advantages in transport properties, pressure drop, and other characteristics. This paper describes one possible way to improve both capacity and energy efficiency of the R744 system for the car air conditioning. It considers the use of a suction line heat exchanger. Four different configurations of the prototype system were tested: without heat exchanger, and with three coaxial heat exchangers having lengths 1.0, 1.5 and 2.0m. All heat exchangers were made from identical pipes.
Results show that both the capacity and the coefficient of performance could be increased by up to 25%. Greater influence is registered at the higher temperatures of the air to the gas cooler.
The results also demonstrate the extent to which suction line heat exchangers can increase compressor discharge temperatures, thereby complicating the task of compressor design and introducing reliability risks.