Refrigerant Charge Imbalance in a Mobile Reversible Air Conditioning-Heat Pump System

2017-01-0177

03/28/2017

Features
Event
WCX™ 17: SAE World Congress Experience
Authors Abstract
Content
This paper presents the study of refrigerant charge imbalance between A/C (cooling) mode and HP (heating) mode of a mobile reversible system. Sensitivities of cooling and heating capacity and energy efficiency with respect to refrigerant charge were investigated. Optimum refrigerant charge level for A/C mode was found to be larger than that for HP mode, primarily due to larger condenser size in A/C mode. Refrigerant charge retention in components at both modes were measured in the lab by quick close valve method. Modeling of charge retention in heat exchangers was compared to experimental measurements. Effect of charge imbalance on oil circulation was also discussed.
Meta TagsDetails
DOI
https://doi.org/10.4271/2017-01-0177
Pages
7
Citation
Feng, L., and Hrnjak, P., "Refrigerant Charge Imbalance in a Mobile Reversible Air Conditioning-Heat Pump System," SAE Technical Paper 2017-01-0177, 2017, https://doi.org/10.4271/2017-01-0177.
Additional Details
Publisher
Published
Mar 28, 2017
Product Code
2017-01-0177
Content Type
Technical Paper
Language