Protection Implementation of Electric Power Steering Based on Functional Safety
2024-01-2305
04/09/2024
- Event
- Content
- To reduce the harm caused by the failure of electronic and electrical system, the application of ISO 26262 functional safety standard in the automotive industry is more and more widespread. As a critical safety-related electronic and electrical system in automobile, electric power steering is very important and necessary to meet the requirements of functional safety. This paper introduces the main development activities of functional safety at software level. In order to realize the purpose of freedom from interference in memory, the safety mechanism of memory protection is proposed in software safety analysis. The memory protection is realized in AUTOSAR architecture by configuration.
- Pages
- 10
- Citation
- Ye, X., Yang, Y., Li, L., Du, J. et al., "Protection Implementation of Electric Power Steering Based on Functional Safety," SAE Technical Paper 2024-01-2305, 2024, https://doi.org/10.4271/2024-01-2305.