The Performance Improvement and Experimental Research of 323 Counterrotating Reactor Torque Converter

932417

9/1/1993

Authors
Abstract
Content
A series of theoretical analysis and experimental research has been carried out on the 323 counterrotating reactor torque converter, from which the cause of low stall torque ratio and maximum efficiency is found, and the relevant improvement measures have been adopted. The experimental results of the improved torque converter show that the stall torque ratio is increased from 4.31 to 5.2, and the maximum efficiency from 81.6% to 82.3%, with the other performance parameters a little better or unchanged.
Meta TagsDetails
DOI
https://doi.org/10.4271/932417
Citation
Ma, W., "The Performance Improvement and Experimental Research of 323 Counterrotating Reactor Torque Converter," International Off-Highway & Powerplant Congress & Exposition, Milwaukee, Wisconsin, United States, September 28, 1993, https://doi.org/10.4271/932417.
Additional Details
Publisher
Published
9/1/1993
Product Code
932417
Content Type
Technical Paper
Language
English