Performance Evaluation of Impact Responses of the Sid-Iis Small Side Impact Dummy

986149

05/31/1998

Event
International Technical Conference on Enhanced Safety of Vehicles
Authors Abstract
Content
A series of side impact tests have been conducted to evaluate the biofidelity of the latest prototype of a small side impact dummy, SID-II s β+(plus). The tests were lateral impacts for the thorax, shoulder, and pelvis, as well as lateral drops for the head, thorax, abdomen, and pelvis. The test data were compared to the response target corridors that were estimated by scaling the cadaver test data to a smaller occupant.
The test results show that the head, should, thorax, abdomen and pelvis of the SID-II s β+ either completely or close to meets the response target corridors, and that its biofidelity has been improved from the previous dummy SID II s B-prototype.
Meta TagsDetails
Pages
10
Citation
Harigae, T., Ueno, M., Sasaki, M., Ohmae, H. et al., "Performance Evaluation of Impact Responses of the Sid-Iis Small Side Impact Dummy," SAE Technical Paper 986149, 1998, .
Additional Details
Publisher
Published
May 31, 1998
Product Code
986149
Content Type
Technical Paper
Language
English