Performance Evaluation of Double-condenser Loop Heat Pipe Onboard Monitor of All-sky X-ray Image (MAXI) in Thermal Vacuum Testing

2005-01-2939

7/11/2005

Authors
Abstract
Content
The thermal performance of the Loop Heat Pipe Radiator System (LHPRS) has been verified in the thermal vacuum testing. LHPRS is used as the heat transport system to reject heat from the Monitor of All-sky X-ray Image (MAXI). Since this LHPRS was designed exclusively for the MAXI system, it has two-condensers in parallel connected to a common evaporator. Since it is possible that the heat transportation deviates to one condenser only, it had to be investigated how the double condensers affect the LHPRS performance under various conditions. Thermal vacuum testing was conducted for the engineering model of the MAXI/LHPRS. In this paper, the test result and performance verification of the MAXI/LHPRS are described.
Meta Tags
Topics
Details
DOI
https://doi.org/10.4271/2005-01-2939
Pages
10
Citation
Nagai, H., and Ueno, S., "Performance Evaluation of Double-condenser Loop Heat Pipe Onboard Monitor of All-sky X-ray Image (MAXI) in Thermal Vacuum Testing," SAE Technical Paper 2005-01-2939, 2005, https://doi.org/10.4271/2005-01-2939.
Additional Details
Publisher
Published
7/11/2005
Product Code
2005-01-2939
Content Type
Technical Paper
Language