Performance Enhancement of the Hybrid III Thorax

860655

02/24/1986

Authors
Abstract
Content
The current Hybrid III Thorax is capable of thoracic deflections up to a maximum of approximately 3 inches. A modified double rib design which allows deflections up to 3.5 inches is proposed and experimentally evaluated. In addition to this increased deflection capability, a Hybrid III thorax utilizing the double rib design exhibited reduced temperature sensitivity and increased durability. Thus the double rib design allows the Hybrid III to become a more repeatable, more durable anthropomorphic test device which may also assess more severe levels of thoracic injury.
Meta TagsDetails
DOI
https://doi.org/10.4271/860655
Pages
8
Citation
Daniewicz, S., Collins, J., and Pritz, H., "Performance Enhancement of the Hybrid III Thorax," SAE Technical Paper 860655, 1986, https://doi.org/10.4271/860655.