Particle Size Variation in Diesel Car Exhaust

790421

02/01/1979

Event
1979 Automotive Engineering Congress and Exposition
Authors Abstract
Content
The Electrical Aerosol Analyzer (EAA) has been used to measure the particle size-distribution of the exhaust aerosol produced by five diesel cars under a variety of steady-state operating conditions. A good correlation was found between simultaneous EAA and filter determinations of mass emission rate for these cars. For the entire range of cars, speeds, and loads tested, the mass median diameter was about 0.1 pm, with a range from 0.05 pm to 0.22 pm. There was no consistent effect of speed on particle size in this group of cars, but there was a slight tendency toward larger particle sizes as the load increased.
Meta TagsDetails
DOI
https://doi.org/10.4271/790421
Pages
12
Citation
Groblicki, P., and Begeman, C., "Particle Size Variation in Diesel Car Exhaust," SAE Technical Paper 790421, 1979, https://doi.org/10.4271/790421.
Additional Details
Publisher
Published
Feb 1, 1979
Product Code
790421
Content Type
Technical Paper
Language
English