Operation Characteristics of a MOS Controlled Thyristor (MCT) Using a Liquid Cooling Approach
929477
08/03/1992
- Event
- Content
- This paper describes the potential of indirect liquid cooling to remove the waste heat generated while a MOS controlled thyristor (MCT) is operating at various power levels and switching frequencies. An MCT is mounted on a copper heat exchanger which is capable of removing up to 50 W of heat while maintaining the case temperature of the MCT below 50°C. At low switching frequencies, the MCT operates as expected at an applied voltage of 90 and 270 V. However, at 270 V, the device fails after a few minutes of continuous operation when the switching frequency is increased to 10 kHz.
- Pages
- 6
- Citation
- Reyes, A., Nguyen, B., Weimer, J., Beam, J. et al., "Operation Characteristics of a MOS Controlled Thyristor (MCT) Using a Liquid Cooling Approach," SAE Technical Paper 929477, 1992, https://doi.org/10.4271/929477.