Observations on 25,000 Hours of Free-Piston-Engine Operation
570042
01/01/1957
- Event
- Content
- THIS paper presents observations of 25,000 hr of testing on five free-piston engines. Endurance test investigations were made especially on the operation of free-piston-engine air compressors and gasifiers.As a result of the data obtained, basic parts of these engines were redesigned for better performance, power, economy, and reliability.
- Pages
- 8
- Citation
- Flynn, G., "Observations on 25,000 Hours of Free-Piston-Engine Operation," SAE Technical Paper 570042, 1957, https://doi.org/10.4271/570042.