Novel use of a Halo Orthosis on Pediatric Anthropomorphic Test Devices (ATDs) in Frontal Sled Test

2019-22-0018

03/31/2020

Event
63rd Stapp Car Crash Conference
Authors Abstract
Content
Children recovering from cervical spine injuries may need a halo orthosis, which rarely fits into traditional child restraint systems (CRS) during motor vehicle travel. The objectives are to affix a halo orthosis to a 3-year-old anthropomorphic test device (ATD) and to explore the effectiveness of alternative safety restraints for these occupants. The head of the ATD was modified to allow proper insertion of halo pins. The ATD was restrained in either a backless booster or a RideSafer Travel Vest (RSTV) with and without the halo orthosis. The shoulder belt routing over the halo bars caused axial rotation of the occupant during frontal impacts, which increased lateral and torsional neck loads compared to tests without the halo. The halo decreased frontal neck shear and bending compared to tests without the halo. Loose fit between the halo vest and the torso of the ATD likely contributed to a concentration of loads in the cervical spine.
Meta TagsDetails
DOI
https://doi.org/10.4271/2019-22-0018
Pages
4
Citation
Mansfield, J., Bolte IV, J., Sribnick, E., Rhodes, C. et al., "Novel use of a Halo Orthosis on Pediatric Anthropomorphic Test Devices (ATDs) in Frontal Sled Test," SAE Technical Paper 2019-22-0018, 2020, https://doi.org/10.4271/2019-22-0018.
Additional Details
Publisher
Published
Mar 31, 2020
Product Code
2019-22-0018
Content Type
Technical Paper
Language
English