New Design Improvements in Gear Pumps and Motors

851536

09/01/1985

Event
1985 SAE International Off-Highway and Powerplant Congress and Exposition
Authors Abstract
Content
The Powermaster external gear pump/motor series offers design improvements which include lower flow ripple (decreased system noise), contamination resistance which equals or exceeds the best available in other designs, retention of high volumetric efficiency at high temperature, suitability for water/oil emulsion and other fire resistant fluids, and materials suitable for underground mining requirements worldwide.
This paper gives the design objectives and how they were met, various designs considered, developmental testing done to prove the chosen design, and details of the established ratings and performance achieved.
Meta TagsDetails
DOI
https://doi.org/10.4271/851536
Pages
12
Citation
Frazer, D., "New Design Improvements in Gear Pumps and Motors," SAE Technical Paper 851536, 1985, https://doi.org/10.4271/851536.