The Method of Measuring Air-Fuel Ratio by Radical Luminescence in High Combustion Pressure

1999-01-0507

03/01/1999

Event
International Congress & Exposition
Authors Abstract
Content
The relations of luminous intensity of the radicals, CH, C2, and OH radical, and the equivalence ratio, ϕ under high combustion pressure region (7.0MPa maximum) were investigated. Luminous intensity of each radical and combustion pressure were experimentally obtained using a constant volume combustion chamber. It was found that luminous intensity of each radical can be expressed as a function of ϕ and the combustion pressure. The estimation of ϕ was done within the region, 0.8<ϕ<1.2 and 2.0MPa<P<7.0MPa using the ratio of luminous intensity of CH and C2 radical, and combustion pressure. The value of ϕ was estimated and compared with the actual value; the accuracy was about ±5.0%.
Meta TagsDetails
DOI
https://doi.org/10.4271/1999-01-0507
Pages
10
Citation
Sawada, H., Suzuki, T., Oguri, Y., and Yoshida, M., "The Method of Measuring Air-Fuel Ratio by Radical Luminescence in High Combustion Pressure," SAE Technical Paper 1999-01-0507, 1999, https://doi.org/10.4271/1999-01-0507.
Additional Details
Publisher
Published
Mar 1, 1999
Product Code
1999-01-0507
Content Type
Technical Paper
Language
English