Measurement of Engine Air Cleaner Efficiency Using Airborne Particle Size Analysis

831262

09/12/1983

Event
1983 SAE International Off-Highway and Powerplant Congress and Exposition
Authors Abstract
Content
Dust loading and efficiency characteristics are discussed for a typical heavy duty diesel engine intake air cleaner. The effects of particle size and dust loading on efficiency are described with illustrative data for a typical system. Instrumentation and measurement techniques are explained.