Measurement of Cycle-by-Cycle AFR using a Fast Response NDIR Analyzer for Cold Start Fuelling Calibration Applications

2006-01-1515

4/3/2006

Authors
Abstract
Content
This paper examines cold start of a gasoline PFI engine using a fast λ (normalised AFR) measurement technique. The technique uses established fast gas sensing equipment and post-processing calculations to obtain λ with a response time T90-10% of 8ms.
The fast λ is compared with UEGO data. Known characteristics of the UEGO include slower T90-10% and output errors when subjected to high quantities of HC; the new technique is shown to avoid these issues.
Five cold starts are performed. Fast λ can resolve each cycle. Differences were seen between the UEGO and fast λ and these are attributed to the characteristics mentioned above. Good repeatability was seen over the starts and the fast λ was similarly repeatable.
This data will be of importance to reduce emissions over this critical part of the drive cycle.
Meta TagsDetails
DOI
https://doi.org/10.4271/2006-01-1515
Citation
Davis, P. and Peckham, M., "Measurement of Cycle-by-Cycle AFR using a Fast Response NDIR Analyzer for Cold Start Fuelling Calibration Applications," SAE 2006 World Congress & Exhibition, Detroit, Michigan, United States, April 3, 2006, https://doi.org/10.4271/2006-01-1515.
Additional Details
Publisher
Published
4/3/2006
Product Code
2006-01-1515