International Space Station United States Oxygen Generator Development Testing

2000-01-2351

07/10/2000

Event
International Conference On Environmental Systems
Authors Abstract
Content
A life test of a liquid anode feed oxygen generator assembly (OGA) using SPEĀ® (United Technologies Corporation, Hamilton Sundstrand Division) membrane technology was terminated in June of 1999. In the total 15,658 hours of operation at MSFC since delivery in 1995, the OGA has produced 2,103 kilograms (kg) (4,632 pounds mass (lbm)) of oxygen, and 263 kg (579 lbm) of hydrogen. Evaluation of cell stack characteristics and oxygen and hydrogen hydrophilic/hydrophobic membrane separators will be discussed.
Meta TagsDetails
DOI
https://doi.org/10.4271/2000-01-2351
Pages
10
Citation
Erickson, R., "International Space Station United States Oxygen Generator Development Testing," SAE Technical Paper 2000-01-2351, 2000, https://doi.org/10.4271/2000-01-2351.
Additional Details
Publisher
Published
Jul 10, 2000
Product Code
2000-01-2351
Content Type
Technical Paper
Language
English