Influence of Stiffness Adjustment of Bearing Slabs on the Dynamic Response of Prefabricated Metro Stations Integrating Temporary and Permanent Structures

2026-99-2618

11/20/2026

Authors
Abstract
Content
In prefabricated metro stations that combine temporary and permanent structural systems - referred to as integrating temporary and permanent structures (ITPS) - the bearing slab functions as a typical locally connected component. Its actual mechanical behavior may deviate substantially from the conventional theoretical assumption of a fully rigid connection, and such deviation could potentially induce non-negligible modifications in the structural response. In this study, we investigate how a reduction in bearing slab stiffness affects the dynamic performance of Shangyong Park Station on Guangzhou Metro Line 11. To this end, we establish a three-dimensional finite element model that explicitly accounts for soil–structure interaction. Dynamic time-history analyses are then performed using E2-level artificial seismic waves as the primary excitation. An equivalent stiffness reduction factor of η = 0.33 is introduced to represent the potential stiffness degradation of the bearing slab. Our numerical results reveal several key findings. First, the stiffness reduction exerts only a limited influence on the site dynamic characteristics: the dominant frequency band and the transfer function properties remain essentially unchanged between the benchmark and reduced cases. Second, the global deformation patterns, the primary load transfer paths, and the spatial distributions of high-response regions all remain largely consistent, indicating that the overall load-bearing framework of the station is not fundamentally altered. Third, different structural components exhibit varying degrees of sensitivity: the concourse slab, which is directly connected to the bearing slab, shows a more noticeable response modification, whereas the equipment slab exhibits relatively minor changes. Overall, the stiffness reduction primarily induces moderate local adjustments in force redistribution within the floor system, without substantially altering the global seismic response of the station. These findings provide a useful reference for the seismic design and structural optimization of similar ITPS prefabricated underground stations.
Meta TagsDetails
DOI
https://doi.org/10.4271/2026-99-2618
Citation
Yu, M., Xiao, S., Dong, Q., and He, G., "Influence of Stiffness Adjustment of Bearing Slabs on the Dynamic Response of Prefabricated Metro Stations Integrating Temporary and Permanent Structures," 2026 2nd International Conference on Transportation Infrastructure and Engineering (ICTIE2026), Shandong, China, April 17, 2026, https://doi.org/10.4271/2026-99-2618.
Additional Details
Publisher
Published
10 hours ago
Product Code
2026-99-2618
Content Type
Technical Paper
Language
English