The Impact Behavior of the Hybrid II Dummy

751145

2/1/1975

Authors
Abstract
Content
The head, chest and femurs of three Hybrid II dummies were impacted with a ballistic pendulum at various angles to determine what differences in accelerometer and femur load cell output would result for a constant energy input. Also evaluated were suspicious tension loads in the femur load cell output when the legs were subjected to obvious off-center impacts during crash tests. It was found that the dummy legs can be subjected to very high torsion and bending loads which can have a significant effect on the femur load cell axial load outputs.
Meta TagsDetails
DOI
https://doi.org/10.4271/751145
Pages
21
Citation
Daniel, R., Trosien, K., and Young, B., "The Impact Behavior of the Hybrid II Dummy," SAE Technical Paper 751145, 1975, https://doi.org/10.4271/751145.