Hydrogen Advanced Loop Heat Pipe

2007-01-3194

07/09/2007

Event
International Conference On Environmental Systems
Authors Abstract
Content
Passive cooling transport in the cryogenic temperature regime still remains a challenging task since problems regarding parasitic heat gains from the surrounding have not been resolved satisfactorily. A recently-introduced concept of Advanced Loop Heat Pipe (or ALHP) had demonstrated an ability to manage “excessive” vapor generation in the compensation chamber. Nitrogen and Neon were successfully utilized as the working fluids to provide cryocooling transports in the temperature range of 80-120K and 30-40K, respectively. A Hydrogen ALHP in 2004 became the first capillary-pumped system to operate in the 20-30K range. This paper will present the ALHP technology in general and the detailed description of the research program/test results in particular.
Meta TagsDetails
DOI
https://doi.org/10.4271/2007-01-3194
Pages
11
Citation
Hoang, T., and Ku, J., "Hydrogen Advanced Loop Heat Pipe," SAE Technical Paper 2007-01-3194, 2007, https://doi.org/10.4271/2007-01-3194.
Additional Details
Publisher
Published
Jul 9, 2007
Product Code
2007-01-3194
Content Type
Technical Paper
Language
English