Hydrocarbons Speciation of Automotive Emissions Using High Speed Gas Chromatography

950513

02/01/1995

Event
International Congress & Exposition
Authors Abstract
Content
A high speed gas chromatography system has been developed for automotive emissions measurement. The system is capable of quantifying hydrocarbons from C2 to C12 compounds. The separation time required for an analysis is only five minutes. Major technical challenges were (1) tandem quick heat cold traps, (2) four parallel ovens design, and (3) the mid-point back flush technique. Demonstrations of the system have been done using FTP75 cold transient phase. The results indicate that the system is well suited for hydrocarbon speciation measurement with very simple and quick operations.
Meta TagsDetails
DOI
https://doi.org/10.4271/950513
Pages
15
Citation
Otsuki, S., Oie, T., and Ishida, K., "Hydrocarbons Speciation of Automotive Emissions Using High Speed Gas Chromatography," SAE Technical Paper 950513, 1995, https://doi.org/10.4271/950513.