Hayes High Airflow Design Rotor for Improved Thermal Cooling and Coning

982248

09/20/1998

Event
Annual Brake Colloquium And Engineering Display
Authors Abstract
Content
Hayes Lemmerz has patented a straight 42 fin rotor design which has air entry from the inboard and outboard side of the brake rotor. In a previous brake colloquium, we reported that a 5% increase airflow occurs in this design compared to the conventional 100% inboard entry rotor. We have now studied the thermal cooling rate and distortion due to temperature on the dynamometer. The current Hayes Airflow Rotor Design has exhibited 100 degrees F lower peak temperature and 50% less coning when compared to current production rotor design. More work is being done to analytically understand the airflow and thermal distortion of the rotor compared to instrumented vehicle tests like DST (Detroit Suburban Traffic), and LACT (Los Angeles City Traffic).
Meta TagsDetails
DOI
https://doi.org/10.4271/982248
Pages
8
Citation
Daudi, A., "Hayes High Airflow Design Rotor for Improved Thermal Cooling and Coning," SAE Technical Paper 982248, 1998, https://doi.org/10.4271/982248.
Additional Details
Publisher
Published
Sep 20, 1998
Product Code
982248
Content Type
Technical Paper
Language
English