FACTORS GOVERNING “OUT-OF-ROUNDNESS” MEASUREMENT 1
230051
1/1/1923
- Content
- It is stated that an out-of-round surface having an even number of high-spots requires a checking instrument that has opposed measuring points; and that, if the number of high-spots on the surface is uneven, an instrument having three-point contact, and one of the points of contact located on the center line between the other two, is necessary. Concerning the use of the three-point method, for close work, the angle between the three points of contact must be selected according to the number of high-spots.Divisions of the subject include types of out-of-roundness and those peculiar to certain machines, the three-point measurnig system, errors of the V-block method, use of the V-block for elliptical objects, other methods of checking elliptical forms and indicator-reading correction. Three items for instrument improvement are suggested to manufacturers.
- Citation
- FRAUENTHAL, A., "FACTORS GOVERNING “OUT-OF-ROUNDNESS” MEASUREMENT 1," Pre-1964 SAE Technical Papers, Warrendale, Pennsylvania, United States, January 1, 1906, https://doi.org/10.4271/230051.