Experimentation of Practical New Technique for Single and Two Simultaneous Diodes Open Faults Automatic Detection and Localization in Six Diodes Three Phase Bridge Rectifier
2008-01-0409
4/14/2008
- Content
- The faulty performance of six diodes three phase rectifier is studied under one and two simultaneous open-diodes conditions. This rectifier is feeding a resistive load. The rectifier three phases currents zero harmonic components and their maximum and minimum values are used as diagnostic indices. A knowledge algorithm is based to get information on which diode is in open-switch fault condition. This algorithm testing shows that the system could not only detect the open-switch fault, but also identify the faulty switches. Presented simulation results confirm the effectiveness of the proposed methodology.
- Citation
- Benslimane, T., "Experimentation of Practical New Technique for Single and Two Simultaneous Diodes Open Faults Automatic Detection and Localization in Six Diodes Three Phase Bridge Rectifier," SAE World Congress & Exhibition, Detroit, Michigan, United States, April 14, 2008, https://doi.org/10.4271/2008-01-0409.