Experimental Analysis of the After-Boiling Phenomenon in a Small I.C.E.
2004-32-0091
09/27/2004
- Event
- Content
- An experimental investigation was conducted on a production 4-cylinder, MPI small S.I. engine, 1.2 dm3 displacement, which was operated at 4000 rpm full load, then brought to idle for a short period and finally switched off. As the coolant flow stops while the metal temperature is quite high, a fraction of coolant vaporizes, pressure and temperature increase and part of the coolant is lost through the radiator pressure relief valve. This phenomenon is often known as after-boiling.Tests were carried out for different values of the idle operation time, while coolant conditions and metal temperature at 26 points of the engine head and liner were monitored for 2 mins before and 15 mins after engine switch-off. The volume of leaked coolant as well as the start and finish of the expulsion process were also recorded.
- Pages
- 8
- Citation
- Bova, S., Piccione, R., Durante, D., and Perrussio, M., "Experimental Analysis of the After-Boiling Phenomenon in a Small I.C.E.," SAE Technical Paper 2004-32-0091, 2004, https://doi.org/10.4271/2004-32-0091.