Expanding the HCCI Operation With the Charge Stratification
2004-01-1756
03/08/2004
- Event
- Content
- A single cylinder CFR research engine has been run in HCCI combustion mode at the rich and the lean limits of the homogeneous charge operating range. To achieve a variation of the degree of charge stratification, two GDI injectors were installed: one was used for generating a homogeneous mixture in the intake system, and the other was mounted directly into the side of the combustion chamber. At the lean limit of the operating range, stratification showed a tremendous improvement in IMEP and emissions. At the rich limit, however, the stratification was limited by the high-pressure rise rate and high CO and NOx emissions. In this experiment the location of the DI injector was in such a position that the operating range that could be investigated was limited due to liquid fuel impingement onto the piston and liner.
- Pages
- 18
- Citation
- Aroonsrisopon, T., Werner, P., Waldman, J., Sohm, V. et al., "Expanding the HCCI Operation With the Charge Stratification," SAE Technical Paper 2004-01-1756, 2004, https://doi.org/10.4271/2004-01-1756.