Examination of the Data Structures of the Bendix Data Recorder
2025-01-8712
To be published on 04/01/2025
- Event
- Content
- Bendix® EC-80™ and certain EC-60™ ABS control units contain an event data recorder called the Bendix® Data Recorder (BDR). Raw BDR data is obtained using commercially available software, however, the translation of the raw data into an event report has only been performed by the manufacturer. In this paper, the raw data structures of the commercially available datasets are examined. It is demonstrated that the data follows uniform and repeatable patterns. The raw BDR data is converted into a conventional report and then validated against translation reports performed by the manufacturer. The techniques outlined in this research allow investigators to access and analyze BDR records independently of the manufacturer and in a way previously not possible.
- Citation
- DiSogra, M., Hirsch, J., and Yeakley, A., "Examination of the Data Structures of the Bendix Data Recorder," SAE Technical Paper 2025-01-8712, 2025, .